Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberBLD18-04557
StatusFinaled
Name BUSALACCHI CUSTOM HOMES LLC
Site Address 2731 S SIMSBURY LN
Project NameLot 9 Blk 1 Graywoods Estates
Customer Number 
ePlanReviewYes
Description
**PASSES TOTAL UA TRADE OFF** Permit for the construction of a new 2429 sq. ft., one story single family dwelling with 3 bedrooms, 2.5 bathrooms, approximately 382 sq. ft. of covered patio/porch and a 1063 sq. ft. attached garage per the approved plans and any notations. R-1B zoning and setbacks per planning. JJN
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/18/20196/19/20196/19/2019APASS
DetailsMike Jordan
John- please call for access Phone #: ###-####
DOC - Permit Finaled6/19/20196/19/20196/19/2019PPASS
DetailsMike Jordan
All issues have been resolved.
BLD-Blower Door Test Results6/19/20196/19/20196/19/2019ADONE
DetailsMike Jordan
4.4
BLD-Final6/14/20196/17/20196/17/2019AFAIL
DetailsMike Jordan
Shawn Phone #: ###-####. Provide R30 insulation in crawl space under floor. Provide the home envelope test results and post. (Blowerdoor). Correction notice posted.
BLD-Framing/Rough-in3/25/20193/26/20193/26/2019APASS
DetailsMike Jordan
reinspect and insulation // Shawn
BLD-Energy code compliance3/26/20193/26/20193/26/2019APASS
DetailsMike Jordan
reinspect and insulation // Shawn
BLD-Framing/Rough-in3/22/20193/22/20193/22/2019PPART
DetailsMike Jordan
Call ahead // Shawn Phone #: ###-####. Ok to insulate. Needs to provide approved fixes for C8,C9 and C10 trusses.
BLD-Framing/Rough-in3/20/20193/21/20193/21/2019ANR
DetailsMike Jordan
shear // Shawn Phone #: ###-####. Needs to complete airseal pack prior to framing inspection.
BLD-Wall Bracing3/20/20193/21/20193/21/2019APASS
DetailsMike Jordan
shear // Shawn Phone #: ###-####. Exterior shear ok. Will check interior OSB and enginnering on framing inspection.
BLD-Wall Bracing3/8/20193/8/20193/8/2019PFAIL
DetailsMike Jordan
Shawn Phone #: ###-####. Provide the engineering. Install missed hardware for the drag truss. Install the missed holdowns, HDU5 and DTT2Z, and sheet the walls and nail per the schedule. bedroom #2 should have a portal. Correction notice posted.
BLD-Foundation1/28/20191/28/20191/28/2019PPASS
DetailsMike Jordan
wall // Nate Phone #: ###-####
BLD-Footing1/28/20191/28/20191/28/2019PCANC
DetailsMike Jordan
Nate Phone #: ###-####
BLD-Footing1/24/20191/25/20191/25/2019APART
DetailsMike Jordan
Shawn Phone #: ###-####. footings were covered with concrete blankets. Ground and form work did meet minimum temps for cold weather concrete.