Permit Information
Permit NumberBLD19-02189
StatusFinaled
Name CONNER CONSTRUCTION LLC
Site Address 3822 N SANDPOINT WAY
Project NameThiry Residence
Customer Number 
ePlanReviewYes
Description
**HILLSIDE** **WUI FOOTHILLS ZONE A** **PRESCRIPTIVE ENERGY REQUIREMENTS**Permit for the construction of a new 3604 sq. ft., two story (first story 2433 sq. ft., second story 1171 sq. ft.) single family dwelling with 3 bedrooms, 3 bathrooms, approximately 460 sq. ft. of covered patio/porch and a 990 sq. ft. attached garage per the approved plans and any notations. A-1 zoning and setbacks per planning. JJN ***SPRINKLERS ARE NOT REQUIRED***LGMA letter from the applicant’s geotechnical engineer indicating that the footing/column subgrade is acceptable must be approved by Public Works prior to scheduling a footing inspection. Please e-mail the stamped inspection approval letter to mjannusch@cityofboise.org and allow 24 hours for subgrade approval processing. Call Melissa Jannusch at 208-608-7168 with questions.

Prior to obtaining a final for the permit, the roof storm drainage system must be inspected by Public Works. Call Melissa Jannusch at 208-608-7168.

The final inspection of the site grading and drainage work shall be done by the design engineer. Written approval shall be submitted to Boise Public Works prior to the issuance of the building final.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final6/11/20206/11/20206/11/2020PPASS
DetailsTony Young
Final Phone #: ###-#### Inspection requested via web by Oleksiy Yanchuk
DOC - Permit Finaled6/11/20206/11/20206/11/2020PPASS
DetailsTony Young
BLD-Final6/10/20206/10/20206/11/2020PPASS
DetailsTony Young
Final Phone #: ###-#### Inspection requested via web by Oleksiy Yanchuk
BLD-Final6/5/20206/8/20206/10/2020APEND
DetailsTony Young
Final Phone #: ###-#### Inspection requested via web by Oleksiy Yanchuk
BLD-Final6/9/20206/9/20206/10/2020PPEND
DetailsTony Young
Final Phone #: ###-#### Inspection requested via web by Oleksiy Yanchuk
BLD-Blower Door Test Results6/9/20206/9/20206/10/2020PPASS
DetailsTony Young
Final Phone #: ###-#### Inspection requested via web by Oleksiy Yanchuk// 2.3
BLD-Final6/4/20206/5/20206/5/2020APART
DetailsTony Young
Final Phone #: ###-#### Inspection requested via web by Oleksiy Yanchuk// ok pending engineer letter,, drainage
BLD-Final4/3/20204/6/20204/6/2020PNR
DetailsTony Young
Building Final Inspection Phone #: ###-#### Inspection requested via web by Oleksiy Yanchuk// needs address, fire caulking, drainage away from foundation and vents, seal front door, cable railing engineering, water in crawl space , crawl handle
BLD-Energy code compliance10/28/201910/29/201910/29/2019PPASS
DetailsTony Young
Insulation Inspection. Thank you! Phone #: ###-#### Inspection requested via web by Clayton Conner
BLD-Framing/Rough-in10/24/201910/25/201910/25/2019APASS
DetailsTell Riley
Soffit and Sheetrock Phone #: ###-#### Inspection requested via web by Clayton Conner//soofits ok per detail on plans//will fire caulk can lights//WIP as they work around the house//ok to continue//
BLD-Framing/Rough-in10/24/201910/25/201910/24/2019ACANC
DetailsTony Young
Soffit and Facia Inspection. Thank you! Phone #: ###-#### >> Inspection requested via web by Clayton Conner Inspection cancelled from web by: Clayton Conner
BLD-Framing/Rough-in10/22/201910/22/201910/22/2019PPASS
DetailsDave Hannah
Framing Inspection Phone #: ###-#### Inspection requested via web by Clayton Conner
BLD-Wall Bracing9/23/20199/24/20199/24/2019APART
DetailsTony Young
Shear Wall Inspection. Thank you. Phone #: ###-#### Inspection requested via web by Clayton Conner// exterior ok to cover after minor fixes
BLD-Foundation7/29/20197/30/20197/30/2019APASS
DetailsTell Riley
pouring around 12--Edgar Phone #: ###-####//need to install hold downs at locations shown on plans//
BLD-Footing7/24/20197/25/20197/25/2019APASS
DetailsDave Hannah
pouring at noon - ready at 9 or 10 // Edgar Phone #: ###-####