Permit Information
Permit NumberBLD19-02470
StatusFinaled
Name UNIFIED CONSTRUCTION LLC
Site Address 251 E FRONT ST Unit: 310
Project NameClark Wardle LLP Suite #310
Customer Number 
ePlanReviewYes
Description
(CLARK WARDLE LLP – SUITE #310) Permit to remodel the third floor Suite 310 into a 3,772 sq ft office space. The adjacent tenant Suite 300 will be remodeled into a 13,453 sq ft office space under BLD19-02469. Work to include: removal of select interior nonbearing walls and doors, construction of new interior non-bearing walls and doors; electrical work; relocation of existing HVAC diffusers; replacing portions of existing ceiling grid; millwork and interior finishes in compliance with Ch. 8 of the 2015 IBC. Approval is contingent upon adhering to the approved plans on file. The 3rd floor corridor is to be re-classified as a non-rated corridor as allowed in buildings with a sprinkler system installed in accordance with 2015 IBC Section 903.3.1.1 per 2015 IBC Section 1020.1. This building is fully Fire Sprinklered with quick response heads. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/18/20199/18/20199/18/2019APASS
DetailsDave Hannah
Please call 30 minutes before inspecting--Thank You, Ellliott
Phone #: ###-#### Inspection requested via web by Elliott Sheffield
FIRE-Final Inspection9/18/20199/18/20199/18/2019PPASS
DetailsJim Page
Fire sprinkler inspection complete, fire alarm inspection is complete, fire extinguisher was placed in discussed location and has a current inspection tag. Final life fire safety inspection for area of work is complete, signatures provided for associated trades on sign off card.

BLD-Framing/Rough-in9/10/20199/11/20199/11/2019PPASS
DetailsDave Hannah
Please Call 208 ###-#### to gain access. At least 30 minutes notice would work well. Phone #: ###-#### Inspection requested via web by Elliott Sheffield
FIRE-Final Inspection8/21/20198/21/20198/21/2019AFAIL
DetailsJim Page
Fire sprinkler modifciations as well as fire alarm modifications are required for area of work, a seperate permit is required for any and all modifications to fire sprinklers and fire alarms.

Please call 30 minuted prior to gain entrance Phone #: ###-#### Inspection requested via web by Elliott Sheffield
BLD-Framing/Rough-in7/24/20197/24/20197/24/2019PPASS
DetailsDave Hannah
Please call 30 minutes+ before arrival---Thanks,Elliott Phone #: ###-#### Inspection requested via web by Elliott Sheffield