BLD-Final | 4/16/2020 | 4/20/2020 | 4/20/2020 | A | PASS |
Tell Riley
|
|
|
Aren **cleared** Phone #: ###-####
|
DOC - Permit Finaled | 4/20/2020 | 4/20/2020 | 4/20/2020 | P | PASS |
Tell Riley
|
|
|
|
BLD-Energy code compliance | 1/10/2020 | 1/10/2020 | 1/10/2020 | P | PART |
Tell Riley
|
|
|
Chris Phone #: ###-####//corrections made//need to post R value cert//do not cover area near gas fireplace per mechanical//
|
BLD-Energy code compliance | 1/9/2020 | 1/9/2020 | 1/9/2020 | P | FAIL |
Tell Riley
|
|
|
chris Phone #: ###-####//plans show R-50 attic insulation on details,, code minimum is R-49,, R 38 batts were installed in some locations//add insulation to meet plans//need mechanical pass on gas fireplace prior to cover//
|
BLD-Framing/Rough-in | 1/6/2020 | 1/6/2020 | 1/6/2020 | P | PASS |
Tell Riley
|
|
|
chris Phone #: ###-####//corrections made//ok to insulate//
|
BLD-Framing/Rough-in | 11/27/2019 | 12/2/2019 | 12/2/2019 | A | FAIL |
Tell Riley
|
|
|
Chris Phone #: ###-####//add bracing to truss tails on overbuild//need airseal completed//add nails to truss hangers//provide truss bearing point is sufficient for existing in center span//get mechanical inspection for fireplace//re-inspection required//
|
BLD-Wall Bracing | 11/12/2019 | 11/12/2019 | 11/12/2019 | P | PASS |
Dave Hannah
|
|
|
Chris Phone #: ###-####
|
BLD-Foundation | 10/23/2019 | 10/24/2019 | 10/24/2019 | P | PART |
Tell Riley
|
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru//WIP//will need to demo exisitng crawl access for and add footing per plan for girder truss bearing//
|
BLD-Footing | 10/22/2019 | 10/23/2019 | 10/23/2019 | A | PASS |
Tell Riley
|
|
|
Phone #: 2089495359 >> Inspection requested via mobile web by Ricardo aggregate constru//footings ok per plans//setbacks ok per plans//need to demo old crawl access to add 3x3 point load footer per plans//
|
BLD-Footing | 10/22/2019 | 10/22/2019 | 10/22/2019 | P | CANC |
Tell Riley
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron Inspection cancelled via mobile web on Tuesday, October 22, 2019.
|