Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD19-03255
StatusUnder Review
Name C & T CONSTRUCTION
Site Address 7773 W CRESTWOOD DR
Project Name10B
Customer NumberBLD19-03229, 03247 - 03257
ePlanReview 
Description
***06/16 PLAN MODIFICATION TO ADD WINDOW TO 2 HOUR SEPARATION WALL*** ***02/18/20 PLAN MODIFICATION TO UPDATE 2 HOUR WALL*** ***DEMO BLD18-03411*** (12 PERMITS FILED WITH BLD19-03229) Permit for the construction of a new 1589 sq. ft., 3 story (first story 189 sq. ft., second story 750 sq. ft., third story 650 sq. ft.) Townhouse with 3 bedrooms, 2.5 bathrooms, approximately 146 sq. ft. of covered patio/porch and a 450 sq. ft. attached garage per the approved plans and any notations. Rescheck Energy Compliance. C-1D zoning and setbacks per planning. ***RDP***
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Framing/Rough-in6/12/20206/12/20206/12/2020APASS
DetailsTell Riley
Inspection requested via web by Carl Funk//ok to insulate//see Joey onsite for correction notes//
BLD-Wall Bracing6/2/20206/2/20206/2/2020PPART
DetailsTell Riley
Firewall Inspection requested via web by Carl Funk//interior gyp shear wall//ok to cover when screws have been added at blocking lines on each floor as discussed//screws per details and email from engineer for gyp shear walls//
BLD-Energy code compliance5/18/20205/18/20205/18/2020APART
DetailsTell Riley
Inspection requested via web by Carl Funk//fire wall insulation only ok//call for shear on gyp//
BLD-Energy code compliance5/15/20205/15/20205/15/2020PNR
DetailsTell Riley
Insulating Firewall Inspection requested via web by Carl Funk//need to fix R21/add R21 in areas noted on walk through//
BLD-Framing/Rough-in5/7/20205/8/20205/8/2020APEND
DetailsTell Riley
Inspection requested via web by Carl Funk//fire separation only//corrections made//need rating for ele heater in separation wall(all Units)//pending ele rough//
BLD-Framing/Rough-in5/7/20205/7/20205/7/2020AFAIL
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by Carl Funk/framing for fire walls ONLY//add nuts and bolts in areas noted//add studs in areas noted//add fire blocking in areas noted//see details for truss connections at fire walls//complete air seal//
BLD-Wall Bracing3/19/20203/20/20203/20/2020APART
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by Carl Funk
BLD-Wall Bracing3/16/20203/17/20203/17/2020AFAIL
DetailsTell Riley
Phone #: ###-#### Inspection requested via web by Carl Funk//need to add nails, fix hold downs nails//did walk through with carl//add hold downs where needed//
BLD-Foundation10/18/201910/18/201910/18/2019PPART
DetailsTell Riley
SERGIO- wall foundation inspection Phone #: ###-####//wip//
BLD-Footing10/17/201910/17/201910/17/2019PPART
DetailsTell Riley
Sergio Phone #: ###-####//ok when bars added for 32" requirement//