BLD-Blower Door Test Results | 4/1/2020 | 4/1/2020 | 4/1/2020 | P | DONE |
Tell Riley
|
|
|
4.77 ACH 50
|
BLD-Final | 4/1/2020 | 4/1/2020 | 4/1/2020 | P | DONE |
Tell Riley
|
|
|
Willy Phone #: ###-####//corrections made//
|
DOC - Permit Finaled | 4/1/2020 | 4/1/2020 | 4/1/2020 | P | PASS |
Tell Riley
|
|
|
|
BLD-Final | 3/30/2020 | 3/31/2020 | 3/31/2020 | A | CANC |
Tell Riley
|
|
|
Willie Phone #: ###-####
|
BLD-Final | 3/26/2020 | 3/27/2020 | 3/27/2020 | A | FAIL |
Tell Riley
|
|
|
willie Phone #: ###-####//Correction notice posted//caulk penetrations at garage wall//remove dust covers from smoke/co detectors//add fall prevention/opening limitaiton devices at windows with sill height less than 24"//post insulation certificate//
|
BLD-Other | 1/30/2020 | 1/31/2020 | 1/31/2020 | A | PASS |
Mike Jordan
|
|
|
Soffit Fireproof inspection - Willie Phone #: ###-####
|
BLD-Energy code compliance | 1/23/2020 | 1/24/2020 | 1/24/2020 | P | PASS |
Tell Riley
|
|
|
Willie Phone #: ###-####
|
BLD-Framing/Rough-in | 1/22/2020 | 1/23/2020 | 1/23/2020 | A | PASS |
Tell Riley
|
|
|
Billy Phone #: ###-####//will need to add 1hr rated soffits per plans and call for inspection//no penetrations
|
BLD-Wall Bracing | 1/7/2020 | 1/8/2020 | 1/8/2020 | A | PART |
Tell Riley
|
|
|
shear // Willy Phone #: ###-####//exterior nailing ok//need to add hold down near front entry where hold down is missed//add nuts and straps at portal frames//check at framing//
|
BLD-Foundation | 12/9/2019 | 12/10/2019 | 12/10/2019 | A | PASS |
Tell Riley
|
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru//blankets onsite//form temps 35-50 degrees while onsite//no rebar//
|
BLD-Footing | 12/8/2019 | 12/9/2019 | 12/9/2019 | P | PASS |
Tell Riley
|
|
|
Phone #: 2089109404 >> Inspection requested via mobile web by Ricardo aggregate constru
|