Permit Information
Permit NumberBLD95-02080
StatusFinaled
Name SMITH DETROIT DIESEL ALLISON I
Site Address 4045 S TRANSPORT ST
Project NameSMITH DETROIT DIESEL
Customer Number 
ePlanReviewNo
Description
TRUCK REPAIR GARAGE * TO ADD 4,800 SQ.FT. SINGLE STORY, CONCRETE MASONRY, TYPE V NONRATED, TRUCK REPAIR AREA. TO THE EXISTING TWO STORY, CONCRETE MASONRY, TYPE V NONRATED, TRUCK REPAIR FACILITY. THE INSTALLATION OF THE FIRE SPRINKLER SYSTEM IS BEING USED FOR ALLOWABLE AREA INCREASE AND FIRE FLOW REQUIREMENTS. ALL CONSTRUCTION PER THE APPROVED PLANS, ATTACHED REQUIREMENT LIST, CABO/ANSI STANDARDS A/117.1, AND THE 1994 EDITION OF THE UBC. MJP PC#773-95 DR#-115-95.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Permanent Occupancy 12/11/199612/11/1996 DONE
Details
INSP - Final10/3/199610/4/199610/4/1996APASS
DetailsJim Storey
10/04/96 301 - TCO -TEMP C OF O ISSUED special insp. report to be delivered to my offic time of temp signoff by everit.
INSP - Final10/1/199610/2/199610/2/1996PFAIL
DetailsJim Storey
10/02/96 301 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED OTH-OTHER AGENCIES NOT APPROVED ele,mech,fire,achd
INSP - Final10/2/199610/2/199610/2/1996 PART
Details
/ / 405 - temp pending knox box
INSP - Final10/1/199610/1/199610/1/1996 FAIL
Details
/ / 405 - alarm system recheck.....tampers still sent as fire alarm, o not activate within first two revolutions
INSP - Final9/30/19969/30/19969/30/1996 FAIL
Details
/ / 405 - c/n issued 5 items, alarms not functional, buld occupied
INSP - Occupancy Sign-off9/30/19969/30/19969/30/1996 F
Code Enf. Insp. (AY) - complys w/DR-115-95
INSP - Final9/27/19969/28/19969/27/1996A
Details
8:30AM
INSP - Conference9/23/19969/23/19969/23/1996 PART
Details
/ / 405 - advised of need to sprinkle under exhaust hood can drop two
INSP - Final9/18/19969/19/19969/19/1996AFAIL
DetailsJim Storey
09/18/96 301 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED
INSP - Final9/17/19969/18/19969/18/1996PCANC
DetailsJim Storey
09/18/96 301 - cancled for am insp.9-19-96
INSP - Framing/Rough-in5/24/19965/28/19965/28/1996APASS
DetailsJim Storey
05/24/96 301 - RF -OK ROOF NAILING/ stair encloser will have false lid below fire membr
INSP - Carpentry5/17/19965/17/19965/17/1996PPASS
DetailsJim Storey
05/17/96 301 - FIRE BLOCKING REQUIRED AT STAIR STRINGER LINE AND USABLE CONF.OK
INSP - Framing/Rough-in4/30/19964/30/19964/30/1996 PASS
DetailsJim Storey
/ / 301 - upper floor and stair framing ok
INSP - Framing/Rough-in4/26/19964/26/19964/26/1996PPART
DetailsJim Storey
04/26/96 301 - CORR-CORREC-CALL FOR REINSP WHEN COMPLETED not all info. on site for she wall configuration.
INSP - Conference4/25/19964/25/19964/25/1996 FAIL
DetailsJim Storey
/ / 301 - WFR -OK WALL FRAMING STAIR NOT FRAMED PER PLAN MUST BE REFRAMED
INSP - Footings4/22/19964/22/19964/22/1996PPASS
DetailsJim Storey
04/22/96 301 - FTG -OK FOOTING CENTER PAD SOUTH WALL
INSP - Foundation4/12/19964/15/19964/15/1996APASS
DetailsJim Storey
04/12/96 301 - FDN -OK FOUNDATION
INSP - Foundation4/12/19964/12/19964/12/1996PPART
Details
south and east sections.
INSP - Footings4/11/19964/11/19964/11/1996PPASS
DetailsJim Storey
04/11/96 301 - FTG -OK FOOTING
INSP - Foundation4/10/19964/10/19964/10/1996PPASS
Details
North wall ok.
INSP - Footings4/8/19964/9/19964/9/1996ANR
DetailsJim Storey
04/09/96 301 - EAST FOOTING N/R FOR INSP. SITE LOCKED NO ACCESSABLITY. N
INSP - Footings4/9/19964/9/19964/9/1996 NR
DetailsJim Storey
/ / 301 - UGA -UNABLE TO GAIN ACCESS WORK N/R FOR INSP. EAST WALL FOOTTING.