Description
(YMCA GUIDED DISCOVERY and NURSERY) This building is not fire sprinkled. System to be installed in the future. To remodel the existing day-care at the YMCA. Work is to include 2 restrooms with children's units, upgrading the existing corridor to 1-hr fire-resistive construction, a small building addition, and upgrading the fire alarm system all per approved drawings, engineering, and plan check notes on file. Separate electrical, plumbing, and mechanical permits are required. A demo permit (BLD96-1556) was issued earlier. PC-230-96 **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/1/199911/1/199911/1/1999APASS
Details
made ok other agencies approved
INSP-Final Inspection10/10/199710/10/199710/10/1997APASS
Details
new alarm system complete, meets full requirements for E3
INSP-Conference5/12/19975/12/19975/12/1997PPART
Details
3pm, grinnel, alarm plan review for downtown y remodel e3 portion ok, advised update of existing not mandated, ron to get plans for remodels to size system
INSP-Conference5/9/19975/12/19975/12/1997ANR
Details
8:30 am, grinnel not ready, rescheduled to 3pm
INSP-Conference5/8/19975/9/19975/9/1997APART
Details
mtng w/ ron @ grinnel-- alarm system requirements revising plans, recheck monday
INSP - Carpentry9/4/19969/4/19969/4/1996PPASS
DetailsWes Worcester
metal joists ok
INSP - Conference9/4/19969/4/19969/4/1996PPART
DetailsWes Worcester
INSP - Final9/4/19969/4/19969/4/1996PNR
DetailsWes Worcester
INSP - Partial final9/3/19969/3/19969/3/1996PPART
DetailsWes Worcester
THIS WAS SET UP FOR THIS A.M. temp occ ok
INSP - Final8/30/19968/30/19968/30/1996 PART
Details
/ / 405 - reinspection for temp pending alarm system upgrade. mag hol from system until smoke detectors installed. issued new c/n requiring alarm system upgrade within 90 days includingpl submittal for approval
INSP - Final8/30/19968/30/19968/30/1996 FAIL
Details
/ / 405 - requesting temp occ of area while finishing stairwell c/n issued...fe's missing, one exit to relocate to approved door no smoke detectors, alarm system does not function properly, no strobes, alarm plans or certificatio
INSP - Partial final8/28/19968/29/19968/29/1996PNR
DetailsWes Worcester
THURS. 3:30 PM need plumbing and mech....looks ok so far
INSP - Temporary occupancy8/26/19968/28/19968/28/1996PNR
DetailsWes Worcester
THEY SAID YOU SAID YOU WOULD BE THERE AT 3:00 Still waiting on tempered glass
INSP - Fire Dept. Request8/14/19968/14/19968/14/1996 PART
Details
/ / 405 - YMCA remodel for childcare - inspection for temp occ w/wes classification as E3 ...correction notice issued....wes to recheck later
INSP - Propriety inspection8/14/19968/14/19968/14/1996PPASS
DetailsWes Worcester
temp occ for nursery ok
INSP - Conference8/8/19968/8/19968/8/1996PPART
DetailsWes Worcester
discussed "hidden stairs"
INSP - Framing/Rough-in8/8/19968/8/19968/8/1996PPART
DetailsWes Worcester
still covering wood penetrations
INSP - Conference8/2/19968/1/19968/2/1996APART
DetailsWes Worcester
discussed pan penetrations w/architect again. also mentioned time schedule and definite grid lines on plans
INSP - Carpentry7/29/19967/29/19967/29/1996PFAIL
DetailsWes Worcester
INSP - Conference7/29/19967/29/19967/29/1996PPART
DetailsWes Worcester
INSP - Framing/Rough-in7/26/19967/29/19967/29/1996ANR
DetailsWes Worcester
still has wood in structure in front of remodel area, maint rm ok
INSP - Carpentry7/8/19967/8/19967/8/1996PPART
DetailsWes Worcester
front store front ok
INSP - Conference7/8/19967/8/19967/8/1996APART
DetailsWes Worcester
Met w/architect reference bldg classification and wood in walls of II-1HR BUILDING. Removing some & covering some, needs clarification of what needs to be done @ expansion
INSP - Framing/Rough-in7/5/19967/8/19967/8/1996ACANC
DetailsCarl Dependahl
07/08/96 340 - 342 area, sent in error....called Wes
INSP - Conference7/3/19967/3/19967/3/1996PPART
DetailsWes Worcester
PM 1:30 GREG - ###-#### -- 19203
INSP - Conference6/28/19967/3/19967/2/1996PCANC
Details
07/03/96 338 - COMPLETED BY GEORGE AND WES WRONG AREA