Permit Information
Permit NumberBLD97-03582
StatusFinaled
Name LIZA M GOUL
Site Address 4522 N KITSAP ST
Project Name 
Customer Number 
ePlanReviewNo
Description
To construct a 2350 sq. ft. two story single family dwelling with a 754 sq. ft. unfinished daylight basement a 862 sq. ft. attached three car garage and 1204 sq. ft. of wood deck per approved plans, all engineering and attached requirement lists. NFPA Standard 13 sprinklers, 30 foot "defensible space" on all sides of structure and class "A" roof system are required. All hillside applications apply. Reward basement wall system to either have special inspection or sign-off by engineer of record to verify that full compliance has been met reqarding ER #5373. All documentation to be submitted to structural inspector. (1st floor 1680 sq. ft.) (2nd floor 670 sq. ft.) Note: Seperate permit will be required to finish basement. ACHD #98-0367 CF #97-30 PC #126 DJO 11/4/98-to finish basement, to add bathroom, bedroom 10x11, storage room. 28 x 12, and shop area 8x14. All work per approved plans. Installation of smoke detectors per ubc section 310.9.m_p
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
INSP - Final7/12/19997/15/19997/15/1999APASS
DetailsWes Worcester
07/14/99 342 - HOWARD ###-#### c/c issued
INSP - Grading Inspection7/12/1999 7/12/1999 BOND
DetailsRita DeYoung
Rough grading is complete. Additional work must be done on sideslope of driveway to reduce steepness of the slope to 2:1. Engineer has recommended a $2000.00 bond to cover cost of this work.
INSP - Final7/1/19997/6/19997/6/1999AFAIL
DetailsWes Worcester
07/06/99 342 - Howard ###-#### need p/w criteria,,,left msg
INSP - Framing/Rough-in6/8/19996/8/19996/8/1999 PART
DetailsCarl Dependahl
/ / 340 - CONF W/BLDR RE HANDRAILS
INSP - Final6/7/19996/7/19996/7/1999 PASS
DetailsJoe Tawney
/ / 406 - FINAL OK ON SPKLR SYSTEM AND ALARM SYSYEM
INSP-Final Inspection6/3/19996/4/19996/4/1999AFAIL
DetailsJoe Tawney
06/04/99 406 - FINAL FAIL SPKLR FLOW SWITCH, ALARM PANEL
INSP - Framing/Rough-in11/5/199811/5/199811/5/1998PPART
DetailsCarl Dependahl
conf w/ bldr re install of glass rails at deck.
INSP - Framing/Rough-in10/29/199810/29/199810/29/1998APASS
DetailsCarl Dependahl
ok to cover.
INSP - Energy code compliance10/26/199810/27/199810/27/1998PPASS
DetailsCarl Dependahl
HOWARD GOUL ###-#### FOR INS INSP...c/n ok, int shear ok. fire sprinklers ok per Joe T.
INSP - Framing/Rough-in10/12/199810/12/199810/12/1998PFAIL
DetailsCarl Dependahl
howard ###-####...need shear walls per eng'r, may have to remove fireplace to do; protect foam insul/block w/ drywall or equal; complete posts at deck & fasten hdwe; add header at mud room wall, fireblocking not complete. ok to insulate & install int shear panels.
INSP - Framing/Rough-in8/10/19988/10/19988/10/1998PNR
DetailsCarl Dependahl
approved insulation system at attic, need listed mat'l used.
INSP - Framing/Rough-in7/27/19987/27/19987/27/1998PNR
DetailsCarl Dependahl
no insp; conf w/ bldr re use of foam plastic insul in roof ass'y...gave rules for use from UBC 2602 re listing, smoke flame etc.
INSP - Foundation7/8/19987/8/19987/8/1998PPART
DetailsCarl Dependahl
rec'd eng's ok for ftg/ fnd system.
INSP - Framing/Rough-in7/8/19987/8/19987/8/1998PNR
DetailsCarl Dependahl
framing/ howard goul/ ###-####...rec'd eng's insp report for foam foundation system; conf w/ bldr: ok to cut T joist resting on wall, for plbg.
INSP - Concrete5/5/19985/5/19985/5/1998PPART
DetailsCarl Dependahl
HOWARD/###-#### - CONCRETE INSP. ON SUPPORT COLUMNS. looks ok, pending eng's letter
INSP - Foundation5/1/19985/1/19985/1/1998APART
DetailsCarl Dependahl
spoke w/ Goul...says struct eng'r has observed, will send approval letter. ok to pour
INSP - Foundation4/30/19984/30/19984/30/1998PFAIL
DetailsCarl Dependahl
howard/###-#### - foundation insp. late afternoon. NO PLANS ONSITE
INSP - Foundation4/23/19984/23/19984/23/1998 FAIL
DetailsWes Worcester
/ / 342 - need engineer's details, stamped and signed as per ICBO and criteria options. Inspection required for ftg, fdn, rebar and stepped ft
INSP - Foundation4/23/19984/23/19984/23/1998PFAIL
DetailsWes Worcester
04/23/98 342 - mother's # ???? ###-####