INSP - Final | 2/5/1999 | 2/5/1999 | 2/5/1999 | P | PASS |
Wes Worcester
|
|
|
02/05/99 342 - ###-#### brian\\the code is *5575
|
INSP - Final | 12/18/1998 | 12/18/1998 | 12/18/1998 | P | FAIL |
Carl Dependahl
|
|
|
BRIAN ###-#### GATE CODE *5575 PER 325 need listing/ NFPA documents for non-std. smoke det system, etc.
|
INSP - Energy code compliance | 8/14/1998 | 8/14/1998 | 8/14/1998 | P | PASS |
Wes Worcester
|
|
|
/ / 342 - *5575 gate entrance code brian ###-####
|
INSP - Framing/Rough-in | 8/13/1998 | 8/14/1998 | 8/13/1998 | A | PART |
Wes Worcester
|
|
|
08/13/98 342 - bryan ###-#### turret ok to cover
|
INSP - Framing/Rough-in | 8/10/1998 | 8/11/1998 | 8/11/1998 | A | PASS |
Wes Worcester
|
|
|
08/11/98 342 - brian ###-#### `~
|
INSP - Foundation | 7/8/1998 | 7/14/1998 | 7/8/1998 | A | CANC |
Wes Worcester
|
|
|
Scheduled by Hello!. Cancelled by Hello! (Last update by [HLO]).
|
INSP - Framing/Rough-in | 6/17/1998 | 6/18/1998 | 6/18/1998 | A | FAIL |
Wes Worcester
|
|
|
06/18/98 342 - BRIAN ###-#### after velectrical need to shr and transfer
|
INSP - Concrete | 4/24/1998 | 4/23/1998 | 4/23/1998 | P | NR |
Carl Dependahl
|
|
|
no insp, conf w/ steve of custom masonry
|
INSP - Concrete | 4/17/1998 | 4/16/1998 | 4/16/1998 | P | NR |
Carl Dependahl
|
|
|
no insp; conf w/ mason re plan and c/n
|
INSP - Framing/Rough-in | 4/9/1998 | 4/10/1998 | 4/10/1998 | A | FAIL |
Wes Worcester
|
|
|
need enginering for hold down, anchor bolts and mud sill installation
|
INSP - Concrete | 4/10/1998 | 4/9/1998 | 4/9/1998 | P | NR |
Carl Dependahl
|
|
|
no insp ... conf. w/ mason re supr-king brick
|
INSP - Framing/Rough-in | 4/7/1998 | 4/8/1998 | 4/8/1998 | A | PART |
Carl Dependahl
|
|
|
###-#### MATT...k web at front & side ok t continue
|
INSP - Concrete | 4/8/1998 | 4/7/1998 | 4/7/1998 | P | NR |
Carl Dependahl
|
|
|
no insp, conf w/ mason on struct brick insp's
|
INSP - Framing/Rough-in | 4/6/1998 | 4/6/1998 | 4/6/1998 | P | PASS |
Wes Worcester
|
|
|
04/06/98 342 - ###-#### witnesses epoxy set, and depth of holes for reba
|
INSP - Framing/Rough-in | 4/3/1998 | 4/3/1998 | 4/3/1998 | P | PART |
Wes Worcester
|
|
|
04/03/98 342 - ###-####
|
INSP - Framing/Rough-in | 4/2/1998 | 4/3/1998 | 4/3/1998 | A | PART |
Wes Worcester
|
|
|
04/02/98 342 - MASONRY MATT ###-####
|
INSP - Framing/Rough-in | 4/1/1998 | 4/2/1998 | 4/2/1998 | A | PART |
Wes Worcester
|
|
|
/ / 342 - MATT ###-####
|
INSP - Concrete | 4/1/1998 | 4/1/1998 | 4/1/1998 | P | PART |
Carl Dependahl
|
|
|
not insp, conf. w/ Marlene
|
INSP - Concrete | 3/31/1998 | 3/31/1998 | 3/31/1998 | P | PART |
Carl Dependahl
|
|
|
need to insp rebar & ladder wire horizontal...ok at rear & side walls, up to 9 courses at front
|
INSP - Framing/Rough-in | 3/30/1998 | 3/31/1998 | 3/31/1998 | A | FAIL |
Wes Worcester
|
|
|
03/31/98 342 - MATT ###-#### OFFICE ###-#### full pg-STEEL REINFORCEMENT
|
INSP - Concrete | 3/19/1998 | 3/19/1998 | 3/19/1998 | P | NR |
Carl Dependahl
|
|
|
conf w/ STEVE OF PINNACLE ENG. RE FOUND REQ'S...KEEP SWO
|
INSP - Concrete | 3/16/1998 | 3/16/1998 | 3/16/1998 | A | NR |
Carl Dependahl
|
|
|
chk'd job, swo placed 3-13
|
INSP - Stop Work Order | 3/13/1998 | 3/13/1998 | 3/13/1998 | A | PASS |
Carl Dependahl
|
|
|
need permit to proceed beyond fnd
|
INSP - Concrete | 3/12/1998 | 3/12/1998 | 3/12/1998 | A | FAIL |
Carl Dependahl
|
|
|
met w/ STATEWIDE, MASON, OWNER; NEED FURTHER ENG'G AND INSP SCHEDULE. FND POURED.
|
INSP - Concrete | 3/10/1998 | 3/10/1998 | 3/10/1998 | A | NR |
Carl Dependahl
|
|
|
conf w/ Brian of Statewide re insp's for fnd & masonry....need manuf's specs for proposed install method of reinf for masonry
|
INSP - Concrete | 3/6/1998 | 3/6/1998 | 3/6/1998 | P | NR |
Carl Dependahl
|
|
|
met w/ statewide const, mason & Dale Yarborough of Gen'l Shale...discussed submittal, need new specs for install of reinf. & ner or eng'g
|
INSP - Concrete | 3/4/1998 | 3/5/1998 | 3/5/1998 | P | FAIL |
Carl Dependahl
|
|
|
###-####...POURED; PROPOSED STRUCT BRICK HOUSE, PERMIT NOT ISSUED; NO BAR EXTENSIONS, SILL ANCHOR BOLTS ONLY????TO MEET GEN'L FRI P.M.
|
INSP - Foundation | 3/4/1998 | 3/4/1998 | 3/4/1998 | A | NR |
Carl Dependahl
|
|
|
NOT FDN INSP, DISCUSSED PLAN & FDN REQ'S W/ BRIAN OF STATEWIDE
|
INSP - Concrete | 2/20/1998 | 2/23/1998 | 2/23/1998 | A | FAIL |
Wes Worcester
|
|
|
02/23/98 342 - statewide ###-#### no access code for gate, no answer at
|