INSP - Final | 10/20/1998 | 10/20/1998 | 10/20/1998 | A | PASS |
Tom Arcoraci
|
|
|
|
INSP - Final | 10/19/1998 | 10/20/1998 | 10/20/1998 | A | FAIL |
Jim Storey
|
|
|
10/20/98 301 - trans to tom0 FN INSP
|
INSP - Final | 10/15/1998 | 10/15/1998 | 10/15/1998 | P | FAIL |
Russ Owen
|
|
|
10/15/98 407 - DOOR OPEN--MAIN GARAGE DOOR--939- 7530 BRANDON
|
INSP - Final | 10/13/1998 | 10/14/1998 | 10/14/1998 | P | FAIL |
Russ Owen
|
|
|
10/14/98 407 - JOHN ###-#### ì
|
INSP - Framing/Rough-in | 9/17/1998 | 9/18/1998 | 9/18/1998 | A | PASS |
Russ Owen
|
|
|
09/18/98 407 - stairs have been corrected.
|
INSP - Framing/Rough-in | 9/17/1998 | 9/17/1998 | 9/17/1998 | | PART |
Russ Owen
|
|
|
/ / 407 - AM: insp, Meet with framer to review winder stairs,framer insist they comply with code, I do not agree,He will seek a second opinion from Bob Archibal
|
INSP - Framing/Rough-in | 9/17/1998 | 9/17/1998 | 9/17/1998 | P | PART |
Russ Owen
|
|
|
09/17/98 407 - PM:insp, Meet with Bob Archibald to rewiew the winder sta they do not comply with code,It appears with some modifications code compliance could be gained.
|
INSP - Framing/Rough-in | 9/15/1998 | 9/16/1998 | 9/16/1998 | P | FAIL |
Russ Owen
|
|
|
09/16/98 407 - has corrction for stairs may not proceed beyond dry wall.
|
INSP - Framing/Rough-in | 9/14/1998 | 9/15/1998 | 9/15/1998 | A | PART |
Russ Owen
|
|
|
09/15/98 407 - allowed to sheet rock portion of house only,note on wall corrections.
|
INSP - Framing/Rough-in | 9/11/1998 | 9/14/1998 | 9/14/1998 | A | FAIL |
Russ Owen
|
|
|
09/14/98 407 - left corrections.o!.
|
INSP - Framing/Rough-in | 9/11/1998 | 9/14/1998 | 9/14/1998 | A | FAIL |
Russ Owen
|
|
|
09/14/98 407 - still has corrections.
|
INSP - Framing/Rough-in | 9/11/1998 | 9/11/1998 | 9/11/1998 | P | CANC |
Russ Owen
|
|
|
09/11/98 407 - JOHN ###-#### REINSPECTION AND ENERGY CODE COMPLIANCE
|
INSP - Framing/Rough-in | 9/9/1998 | 9/9/1998 | 9/9/1998 | A | FAIL |
Russ Owen
|
|
|
09/09/98 407 - left corrections.
|
INSP - Framing/Rough-in | 9/4/1998 | 9/8/1998 | 9/9/1998 | A | CANC |
Russ Owen
|
|
|
09/09/98 407 - unable to do this today wil do tomorrow.
|
INSP - Framing/Rough-in | 9/1/1998 | 9/2/1998 | 9/2/1998 | A | NR |
Russ Owen
|
|
|
need other approvals.
|
INSP - Framing/Rough-in | 9/2/1998 | 9/2/1998 | 9/2/1998 | | NR |
Russ Owen
|
|
|
09/02/98 407 - need mechanical and electrical before frame insp.
|
INSP-Conference | 9/1/1998 | 9/1/1998 | 9/1/1998 | P | |
Jack Frank
|
|
|
chris ###-####
|
INSP - Framing/Rough-in | 8/28/1998 | 8/28/1998 | 8/28/1998 | A | PASS |
Russ Owen
|
|
|
08/28/98 407 - this was one on 8/27/98. shear nailing only.
|
INSP - Wall cover | 8/27/1998 | 8/27/1998 | 8/27/1998 | P | PASS |
Russ Owen
|
|
|
siding had begain with out approval remaning shear nailing ok as directed to add more fasteners.
|
INSP - Framing/Rough-in | 8/25/1998 | 8/26/1998 | 8/26/1998 | P | FAIL |
Russ Owen
|
|
|
08/28/98 407 - john ###-#### ì
|
INSP - Foundation | 7/1/1998 | 7/2/1998 | 7/2/1998 | A | CANC |
Russ Owen
|
|
|
07/02/98 407 - Randy ###-#### footings done day before.
|
INSP - Foundation | 7/1/1998 | 7/1/1998 | 7/1/1998 | P | PART |
Russ Owen
|
|
|
EARLY START PERMIT,NO APPROVED PLANS AT THE SITE
|