INSP - Final | 6/16/1999 | 6/16/1999 | 6/17/1999 | A | PASS |
Alan Hauser
|
|
|
c/c #17547
|
INSP - Final | 6/15/1999 | 6/16/1999 | 6/16/1999 | A | PASS |
Alan Hauser
|
|
|
06/16/99 350 - ###-#### DUANE//FINAL
|
INSP - Final | 6/15/1999 | 6/16/1999 | 6/16/1999 | A | PASS |
Alan Hauser
|
|
|
06/16/99 350 - Dwain ###-####, access code 5584. Crawlspace access locat other side of house.
|
INSP - Final | 6/14/1999 | 6/14/1999 | 6/14/1999 | P | FAIL |
Alan Hauser
|
|
|
06/14/99 350 - corrections
|
INSP - Final | 6/8/1999 | 6/9/1999 | 6/9/1999 | A | FAIL |
Jim Sly
|
|
|
06/09/99 316 - C/N...Energy code, Electr final and misc.
|
INSP - Energy code compliance | 4/28/1999 | 4/28/1999 | 4/28/1999 | P | PASS |
Tom Arcoraci
|
|
|
04/28/99 408 - Dwayne ###-####
|
INSP - Framing/Rough-in | 4/27/1999 | 4/27/1999 | 4/27/1999 | P | PASS |
Tom Arcoraci
|
|
|
04/27/99 408 - reinspect framing/call first/ Dwayne ###-####
|
INSP - Framing/Rough-in | 4/23/1999 | 4/26/1999 | 4/26/1999 | P | FAIL |
Jim Sly
|
|
|
04/26/99 316 - Complete prev corr........NR
|
INSP - Framing/Rough-in | 4/23/1999 | 4/23/1999 | 4/23/1999 | | PART |
Jim Sly
|
|
|
/ / 316 - SHEAR WALL ONLY.....OK
|
INSP - Framing/Rough-in | 4/23/1999 | 4/23/1999 | 4/23/1999 | P | FAIL |
Tom Arcoraci
|
|
|
04/23/99 408 - Dewayne ###-####
|
INSP - Framing/Rough-in | 4/20/1999 | 4/20/1999 | 4/20/1999 | P | FAIL |
Jim Sly
|
|
|
04/20/99 316 - C/N....Gar front HDs not per appr plan.....OK to side res
|
INSP - Concrete | 3/18/1999 | 3/19/1999 | 3/19/1999 | A | PART |
Jim Sly
|
|
|
03/19/99 316 - Wall and rebar OK....Setbks? No appr plan early start
|
INSP - Foundation | 3/18/1999 | 3/18/1999 | 3/18/1999 | P | FAIL |
Jim Sly
|
|
|
03/18/99 316 - Footing and bar OK at gar front only...setbks?...No appr
|