Permit NumberBLD99-01689
StatusFinaled
Name DR CHAD ROSKELLEY
Site Address 2033 E SUMMERSWEET DR
Project Name 
Customer Number 
ePlanReviewNo
Description
To construct a new 2,058 sq.ft. dentist's office tenant space in shell building (BLD99-1312) per approved plans on file. Work to include constructing two accessible restrooms, demolishing portions of existing slab to allow for new utility lines then repouring, construction of one hour rated tenant separation walls, infill existing exterior overhead door opening with new exterior wall with new exterior door and window, new interior walls and doors, construction of one hour fire rated medical gas room with one hour rated door, interior finish, new suspended ceiling, new sprinkler work, new mechanical, new plumbing, and new electrical work. NOTE: This building is fully fire sprinklered for area increase. (P.C.#436-99) JCB
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/13/199910/14/199910/14/1999APASS
DetailsRuss Owen
CARL-- ###-#### FN OCC--PLANS & PERMIT ARE AT FRONT DESK-IN DENTIST OFFICE
Permanent Occupancy 10/14/199910/14/1999 DONE
Details
BLD-Final10/8/199910/8/199910/8/1999PCANC
Details
CARL--- ###-#### FN OCC--PLANS & PERMIT ARE AT PERMIT AT FRONT DESK AT DENTIST OFFICE done by 340
BLD-Final10/5/199910/5/199910/5/1999PPART
DetailsRuss Owen
CARL-- ###-#### FN OCC---PER PERRY AFTER 3:30 need mechanical chase done per engineering
BLD-Final10/1/199910/4/199910/4/1999AFAIL
DetailsRuss Owen
CARL ###-####//301 AREA, TOOK FOR RUSS, NEED 1 HR. LISTING ON MED. GAS ROOM DOOR, BRACE COMPRESSOR PLATFORM, NEED FIRE OK. RECALL
FIRE-Final Inspection10/4/199910/4/199910/4/1999AFAIL
DetailsRick Jackson
Carl ###-#### ned gas identification, ahv shutdown not tested
FIRE-Final Inspection10/1/199910/4/199910/4/1999PPASS
DetailsRick Jackson
CARL ###-#### occupancy approved
BLD-Framing/Rough-in9/23/19999/24/19999/24/1999AFAIL
Details
LARRY- ###-#### CEILING GRID Spreader bars & lights- fire & mech.
INSP - Framing/Rough-in9/1/19999/2/19999/2/1999APART
DetailsJim Storey
09/02/99 301 - tennent wall ok at washer / gas rm pending arch design
INSP - Framing/Rough-in8/26/19998/27/19998/27/1999APART
DetailsJim Storey
08/27/99 301 - C/N PENDING RESUBMITALS OK TO COVER ALL OTHER AREAS
INSP - Framing/Rough-in8/26/19998/26/19998/26/1999PFAIL
DetailsRuss Owen
/ / 407 - NP APPROVED PLANS.
INSP - Framing/Rough-in8/25/19998/26/19998/26/1999PFAIL
DetailsJim Storey
08/26/99 301 - trans to russ