Final | 4/4/2001 | 4/4/2001 | 4/4/2001 | P | PASS |
Marv Burrus
|
|
|
###-####. corrections completed. ok. 4/4/2001 2:18:25 PM
|
Final | 3/30/2001 | 3/30/2001 | 3/30/2001 | P | FAIL |
Marv Burrus
|
|
|
John ###-####. NEC; 210-52. recepticles required within 6ft of opening. (kitchen), inoperative recepticle in great room. called contractor. 3/30/2001 2:01:57 PM
|
Permanent Service | 3/16/2001 | 3/19/2001 | 3/19/2001 | A | PASS |
Marv Burrus
|
|
|
###-#### John . perm/svc. ok.
p/s oh r bullit ele #0445
blaser sub no. 8
(service-entrance conductors to weather-head need to be shortened.
3/19/2001 11:09:01 AM
|
Permanent Service | 3/15/2001 | 3/16/2001 | 3/16/2001 | A | PART |
Marv Burrus
|
|
|
###-####. 3/15/2001 4:12:45 PM. grounding ufer conductor ok. 3/16/2001 8:49:16 AM
|
Permanent Service | 3/14/2001 | 3/15/2001 | 3/15/2001 | A | PART |
Marv Burrus
|
|
|
and ufer ground John ###-####. ufer grounding conductor ok of concrete pour. 3/15/2001 10:27:06 AM
|
Electrical Rough-In | 2/12/2001 | 2/13/2001 | 2/13/2001 | A | FAIL |
Marv Burrus
|
|
|
###-####. nec: 300-4(a)(1). bored holes; clearances. nec: 300-4(d). cables parallel to framing members. 2/13/2001 10:05:47 AM
|
Electrical Rough-In | 2/13/2001 | 2/13/2001 | 2/13/2001 | P | PART |
Marv Burrus
|
|
|
###-####. partial; corrections completed. 2/13/2001 4:46:56 PM
|