Final | 11/1/2002 | 11/4/2002 | 11/4/2002 | A | PASS |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 11/01/2002 at 15:59:04. Contact: ###-####.
|
Final | 10/28/2002 | 10/28/2002 | 10/28/2002 | P | FAIL |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 10/28/2002 at 10:34:09. Contact: ###-####.
(C) Countertops. In kitchens and dining rooms of dwelling units, receptacle outlets for counter spaces shall be installed in accordance with 210.52(C)(1) through (5).
210.70 Lighting Outlets Required.
Lighting outlets shall be installed where specified in 210.70(A), (B), and (C).
10/29/2002 10:09:08 AM
|
Final | 10/21/2002 | 10/22/2002 | 10/22/2002 | A | FAIL |
Pat Lass
|
|
|
Contact: ###-####.
410.8 Luminaires (Fixtures) in Clothes Closets.
(C) Luminaire (Fixture) Types Not Permitted.
For a final inspection in the city of Boise all of the electrical must be complete and in working order. This includes the installation of lamps in all lighting fixtures.
314.17 Conductors Entering Boxes, Conduit Bodies, or Fittings.
(B) Metal Boxes and Conduit Bodies.
110.12 Mechanical Execution of Work.
(A) Unused Openings.
II. 600 Volts, Nominal, or Less
110.26 Spaces About Electrical Equipment.
Sufficient access and working space shall be provided and maintained about all electric equipment
(1) Indoor. Indoor installations shall comply with 110.26(F)(1)(a) through (d).
210.70 Lighting Outlets Required.
Lighting outlets shall be installed where specified in 210.70(A), (B), and (C).
210.52 Dwelling Unit Receptacle Outlets.
Receptacle outlets required by this section shall be in addition to any receptacle that is part of a luminaire (lighting fixture) or appliance, located within cabinets or cupboards
(C) Countertops. In kitchens and dining rooms of dwelling units, receptacle outlets for counter spaces shall be installed in accordance with 210.52(C)(1) through (5).
330.30 Securing and Supporting. (C) At Terminations. Cables containing four or fewer conductors, sized no larger than 10 AWG, shall be secured within 300 mm (12 in.) of every box,
10/22/2002 11:32:15 AM
|
Final | 10/21/2002 | 10/21/2002 | 10/21/2002 | P | CANC |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 10/21/2002 at 10:08:38. Contact: ###-####.
|
Rough-In Permanent Service | 10/1/2002 | 10/1/2002 | 10/1/2002 | P | PASS |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 10/01/2002 at 11:07:01. Contact: ###-####.
R/I to Pool equipment covered without inspection, no bonding inspection on pools
P/S U/G N Ok 10/1/2002 2:17:36 PM
|
Rough-In Permanent Service | 9/5/2002 | 9/5/2002 | 9/5/2002 | P | FAIL |
Tim McCullough
|
|
|
Scheduled by a contractor via Hello! on 09/05/2002 at 08:38:30. Contact: ###-####.
corr. bond.gr. buss to enclosure ,dead front needed for ser.eq. tighten all term.
talked with installer. 9/5/2002 11:19:43 AM
|
Rough-In Permanent Service | 9/4/2002 | 9/4/2002 | 9/4/2002 | P | PASS |
Tim McCullough
|
|
|
Scheduled by a contractor via Hello! on 09/04/2002 at 10:39:20. Contact: ###-####.
not ready 9/4/2002 1:30:11 PM
|
Rough-In Permanent Service | 8/26/2002 | 8/26/2002 | 8/26/2002 | P | FAIL |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 08/26/2002 at 10:51:08. Contact: ###-####. Equipment grounding conductor not in terminal properly, neutral in sub panel not isolated, and undersized grounding electrode conductor. 8/26/2002 2:28:31 PM
|
Rough-In Permanent Service | 6/19/2002 | 6/19/2002 | 6/19/2002 | P | FAIL |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 06/19/2002 at 08:11:35. Contact: ###-####.
bad connections in Main panel neutral to sub panel and ground
requires acorn lugg to electrode 6/19/2002 2:22:15 PM
|
Electrical Rough-In | 5/8/2002 | 5/8/2002 | 5/8/2002 | P | PASS |
Jim Schmer
|
|
|
Scheduled by a contractor via Hello! on 05/08/2002 at 11:00:03. Contact: ###-####.
|
Electrical Rough-In | 5/6/2002 | 5/6/2002 | 5/6/2002 | P | NR |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 05/06/2002 at 07:43:35. Contact: ###-####. COW most everything you can think of was wrong Jim will have another conf. 5/6/2002 3:45:12 PM
|
Electrical Rough-In | 5/1/2002 | 5/1/2002 | 5/1/2002 | P | PASS |
Jim Schmer
|
|
|
Scheduled by a contractor via Hello! on 05/01/2002 at 11:09:02. Contact: ###-####. conference only - jms 5/1/2002 2:38:47 PM
|
Electrical Rough-In | 4/19/2002 | 4/22/2002 | 4/22/2002 | A | PASS |
Marv Burrus
|
|
|
Scheduled by a contractor via Hello! on 04/19/2002 at 15:42:44. Contact: ###-####. conference. 4/22/2002 9:55:46 AM
|