Final | 10/21/2002 | 10/22/2002 | 10/22/2002 | A | FAIL |
Jack Frank
|
|
|
call 1st before insp -dave; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie 210.52(C) outlet needed left of sink, 210.52(A) outlet required in dinning rm window wall, needs gfci for island counter, where grd outlets are on ungrd circuit, outlets in unfinished basement, adn 210.70 3 way for stairs met with contractor 10/22/2002 11:07:27 AM
|
Electrical Rough-In | 4/9/2002 | 4/10/2002 | 4/10/2002 | A | FAIL |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 04/09/2002 at 16:23:13. Contact: ###-####.
box fill and grounds made up properly 4/10/2002 11:53:57 AM
|
Electrical Rough-In | 4/10/2002 | 4/10/2002 | 4/10/2002 | P | PART |
Jack Frank
|
|
|
###-#### DAVE part r/i ok 4/10/2002 4:47:42 PM
|
Rough-In Permanent Service | 4/5/2002 | 4/5/2002 | 4/5/2002 | P | FAIL |
Jack Frank
|
|
|
###-#### cheryl partial correction posted called 250.50,52, 300.4, 210.52 (ABC) 310.15 derate over 3 conductors in raceway, 312. 5(AC) sub panel 4/5/2002 3:21:57 PM
|
Electrical Rough-In | 3/27/2002 | 3/28/2002 | 3/28/2002 | A | PASS |
Jim Schmer
|
|
|
###-#### DAVE ceiling only!! 3/28/2002 8:36:07 AM
|
Permanent Service | 3/26/2002 | 3/26/2002 | 3/26/2002 | P | PASS |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 03/26/2002 at 07:38:46. Contact: ###-####.
p/s o/h reconnect ok 3/26/2002 4:22:22 PM
|