Final | 10/17/2002 | 10/18/2002 | 10/18/2002 | A | PASS |
Jack Frank
|
|
|
garage code 0973 and 0974 ###-#### ok 10/18/2002 12:10:36 PM
|
Final | 10/2/2002 | 10/2/2002 | 10/2/2002 | P | FAIL |
Jack Frank
|
|
|
duplex 0973 0974 garage codes; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung cor. posted called left message 110.26(F)(2) remove phone equip from below p/s, 314.16 box size end of counter both units, 110.3 (B)and 300.10 shall not use steel flex at non metallic boxes or alter boxes both units 210.8(A)(6)and 210.52(B&C)all outlets that serve kit. counter shall have gfci, and be on small appliance branch circuit counter desk in dinning rm 10/2/2002 5:49:34 PM
|
Rough-In Permanent Service | 6/17/2002 | 6/18/2002 | 6/18/2002 | P | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 06/17/2002 at 15:05:44. Contact: ###-####. some boxes not set flush with sheet rock, I let them know all other boxes shall be flush r/i ok 6/18/2002 4:59:36 PM
|
Permanent Service | 6/17/2002 | 6/17/2002 | 6/17/2002 | P | PASS |
Jack Frank
|
|
|
p/s u/g new ok
|
Rough-In Permanent Service | 6/17/2002 | 6/17/2002 | 6/17/2002 | P | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 06/17/2002 at 09:21:51. Contact: ###-####. p/s only cor. posted called 300.4 11/4and nail plates see added p/s inspection 6/17/2002 5:51:46 PM
|
Rough-In Permanent Service | 6/14/2002 | 6/14/2002 | 6/14/2002 | P | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 06/14/2002 at 09:03:08. Contact: ###-####. fail called condos one service to building only he has 2 service laterals 6/14/2002 6:02:11 PM no cor. posted 6/14/2002 6:20:29 PM
|
Rough-In Permanent Service | 5/30/2002 | 5/31/2002 | 5/31/2002 | A | PASS |
Tim McCullough
|
|
|
TRACY ###-####
ri/ok
ps/ug/new/ok 5/31/2002 5:00:07 PM
|
Rough-In Permanent Service | 5/29/2002 | 5/30/2002 | 5/30/2002 | A | FAIL |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 05/29/2002 at 09:29:04. Contact: ###-####. building not dry sheeted called contractor 5/30/2002 10:10:38 AM
|