Final | 3/11/2003 | 3/11/2003 | 3/11/2003 | P | PASS |
Pat Lass
|
|
|
ALAN; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
Electrical Rough-In | 2/25/2003 | 2/26/2003 | 2/26/2003 | A | PART |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 2/25/2003 at 12:05:20 PM. Contact: ###-####. ceilings 3 marked print ok 2/26/2003 9:24:17 AM
|
Rough-In Permanent Service | 2/19/2003 | 2/20/2003 | 2/20/2003 | A | PASS |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung r/i ceilings ok
p/s u/g new ok 2/20/2003 9:04:24 AM
|
Electrical Rough-In | 2/4/2003 | 2/5/2003 | 2/5/2003 | A | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 02/04/2003 at 19:08:06. Contact: ###-####. ok cover ceiling except for areas marked mark on the print 2/5/2003 11:04:25 AM
|
Rough-In Permanent Service | 2/4/2003 | 2/5/2003 | 2/5/2003 | A | FAIL |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 02/04/2003 at 19:09:12. Contact: ###-####. grounding not correct needs the grounding electrode to building steel 2/5/2003 11:05:32 AM
|
Rough-In Permanent Service | 2/3/2003 | 2/4/2003 | 2/4/2003 | A | FAIL |
Pat Lass
|
|
|
ceiling insp- allan; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
grounding in boxes and service 2/4/2003 10:46:37 AM
|
Electrical Rough-In | 1/27/2003 | 1/27/2003 | 1/27/2003 | P | PASS |
Pat Lass
|
|
|
allen; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
|
Electrical Rough-In | 1/17/2003 | 1/17/2003 | 1/17/2003 | P | PART |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 01/17/2003 at 07:36:44. Contact: ###-####.
|
Electrical Rough-In | 12/30/2002 | 12/30/2002 | 12/30/2002 | P | PASS |
Tim McCullough
|
|
|
Scheduled by a contractor via Hello! on 12/30/2002 at 07:40:26. Contact: ###-####.
ri/ok 12/30/2002 3:22:11 PM
|
Electrical Rough-In | 12/16/2002 | 12/16/2002 | 12/16/2002 | P | PART |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 12/16/2002 at 08:55:12. Contact: ###-####.
3 rooms left 12/16/2002 4:05:13 PM
|
Electrical Rough-In | 12/3/2002 | 12/4/2002 | 12/4/2002 | A | FAIL |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 12/03/2002 at 12:00:37. Contact: ###-####.
Loose set screws, unsecured boxes, over 360 deg. bend. 12/4/2002 8:52:40 AM
|
Electrical Rough-In | 12/4/2002 | 12/4/2002 | 12/4/2002 | P | PART |
Pat Lass
|
|
|
allan; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
Partial wall R/I Ok 12/4/2002 4:22:17 PM
|
Electrical Rough-In | 10/30/2002 | 10/31/2002 | 10/31/2002 | P | PART |
Pat Lass
|
|
|
ground; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung
U/G ok 10/31/2002 4:11:50 PM
|