Final | 1/14/2003 | 1/14/2003 | 1/14/2003 | P | PASS |
Jack Frank
|
|
|
Key is under 2x6 on deck railing. ; Phone #: ###-#### Internet Inspection Request from: Joe Thomas ok cor. made 1/14/2003 6:27:15 PM
|
Final | 1/10/2003 | 1/13/2003 | 1/13/2003 | A | FAIL |
Jack Frank
|
|
|
Key is located at back door on deck railing under 2x6 board. ; Phone #: ###-#### Internet Inspection Request from: Joe Thomas cor. fee due posted called 210.52(A) outlet required room off of laundry rm by access under stairs, line and load outlet counter by refer, needs gfci grd outlet on ungrd circuit hallway 1/13/2003 11:22:48 AM
|
Electrical Rough-In | 12/12/2002 | 12/12/2002 | 12/12/2002 | P | PASS |
Jack Frank
|
|
|
CALL HEATH FIRST ###-#### ok 12/12/2002 4:28:58 PM
|
Electrical Rough-In | 12/11/2002 | 12/11/2002 | 12/11/2002 | P | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 12/11/2002 at 10:32:14. Contact: ###-####. cor. posted 300.14, 250.66 bond water with #4 200.7 old wiring white shall not be used as phase wire, 210.70 light fixture shall light back area, 314.23 cutin boxes shall be rigidly mounted in finish surfaces, 314.20 boxes set back more than 1/4 inch check out all old wiring 12/11/2002 5:56:44 PM
|
Electrical Rough-In | 12/9/2002 | 12/9/2002 | 12/9/2002 | P | FAIL |
Jack Frank
|
|
|
###-#### heath upstairs inspect on receptacle replacements nr needs plans at job site 12/9/2002 3:58:16 PM
|
Permanent Service | 11/21/2002 | 11/21/2002 | 11/21/2002 | P | PASS |
Jack Frank
|
|
|
concrete is poured for ufer ground. Also, need O.K. for permanent service on exterior of house.; Phone #: ###-#### Internet Inspection Request from: Joe Thomas
p/s u/g new ok 11/21/2002 3:49:16 PM
|
Electrical Rough-In | 11/19/2002 | 11/19/2002 | 11/19/2002 | P | PART |
Jack Frank
|
|
|
r/i for concrete cover of elecrode only
|
Final | 11/19/2002 | 11/19/2002 | 11/19/2002 | P | CANC |
Jack Frank
|
|
|
Ufer ground inspection. Contractor is moving window wells up and will add backfill to achieve proper cover.; Phone #: ###-#### Internet Inspection Request from: Joe Thomas see added r/i 11/19/2002 5:29:18 PM
|
Permanent Service | 11/18/2002 | 11/19/2002 | 11/19/2002 | A | NR |
Jack Frank
|
|
|
Ufer ground inspection on North side of the home in the back of the lot.; Phone #: ###-#### Internet Inspection Request from: Joe Thomas called 11/19/2002 10:42:41 AM
|