Final | 10/9/2003 | 10/10/2003 | 10/10/2003 | A | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 10/9/2003 at 10:10:40 AM. Contact: ###-####. done by JIM S Mike K and Joe R 10/10/2003 10:53:39 AM
|
Electrical Rough-In | 7/24/2003 | 7/24/2003 | 7/24/2003 | P | PART |
Jack Frank
|
|
|
allen; Phone #: ###-#### Internet Inspection Request from: Annette Moore u/g for a/c 7/24/2003 2:56:09 PM
|
Electrical Rough-In | 5/2/2003 | 5/2/2003 | 5/2/2003 | P | PASS |
Tim McCullough
|
|
|
Scheduled by a contractor via Hello! on 5/2/2003 at 8:42:45 AM. Contact: ###-####.
tr ench ok 5/2/2003 4:51:37 PM
|
Electrical Rough-In | 2/26/2003 | 2/26/2003 | 2/26/2003 | P | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 2/26/2003 at 9:54:17 AM. Contact: ###-####. u/g out front in courtyard ok 2/26/2003 3:30:53 PM
|
Rough-In Permanent Service | 2/15/2003 | 2/18/2003 | 2/18/2003 | A | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 2/15/2003 at 8:00:31 AM. Contact: ###-####. r/i basement ok
p/s u/g new ok 2/18/2003 11:07:10 AM
|
Electrical Rough-In | 2/3/2003 | 2/3/2003 | 2/3/2003 | P | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 02/03/2003 at 09:46:09. Contact: ###-####. ok 2/3/2003 12:19:52 PM
|
Electrical Rough-In | 1/30/2003 | 1/31/2003 | 1/31/2003 | P | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 01/30/2003 at 19:26:06. Contact: ###-####. cor. posted met contractor, 300.4 nail plates and 11/4 , 314.43 no screws in plastic boxes, 314.16 box fill, 250.148 grd all metal boxes 404.4 remove switches from tub space 1/31/2003 1:32:36 PM
|
Electrical Rough-In | 1/8/2003 | 1/8/2003 | 1/8/2003 | P | PART |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 01/08/2003 at 09:35:10. Contact: ###-####. bonding in crawl space 1/8/2003 3:32:08 PM
|
Electrical Rough-In | 12/24/2002 | 12/24/2002 | 12/24/2002 | P | PART |
Jack Frank
|
|
|
soffits ok only
|
Rough-In Permanent Service | 12/23/2002 | 12/24/2002 | 12/24/2002 | A | CANC |
Jack Frank
|
|
|
###-#### coe. posted for p/s called 314.28(A)(2) angle pull from ct can to disconnect entries, 250.66, 92, 24, size of bonding conductors, bond ct can, tie grounded and grounding together see added r/i 12/24/2002 2:21:37 PM
|