Final | 7/15/2003 | 7/18/2003 | 7/18/2003 | A | PASS |
Joe Ray
|
|
|
Ready for re-inspection, AFTER 10:30 AM per customer.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
|
Final | 4/21/2003 | 4/22/2003 | 4/22/2003 | A | CANC |
Joe Ray
|
|
|
We installed a DP 50amp GFCI breaker in the garage panel, ran a 3/4" emt into crawlspace, changed to 3/4" smurf thru crawlspace, changed to 3/4" pvc #80 as we exited the foundation vent up to the RT Disconnect on the back of the house. We ran 1" pvc #80 from this disc. to the hot tub, changed to 1" LTNM flex inside the tub. We pulled #8 thhn's from panel to disc., and pulled #6 thhn's from disc. to tub. There is an existing outdoor receptacle to left of the sliding glass door(right around corner).; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
|
Electrical Rough-In | 2/12/2003 | 2/13/2003 | 2/13/2003 | P | FAIL |
Jack Frank
|
|
|
###-#### cor. posted called 314.43 no screws alled in non metallic boxes and new fixtures in garage not installed watch for access hole in back of fixture for box 2/13/2003 1:35:01 PM
|