Final | 11/17/2005 | 11/17/2005 | 11/17/2005 | A | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 11/17/2005 at 6:08:52 AM. Contact: ###-####. ok
|
Final | 11/15/2005 | 11/15/2005 | 11/15/2005 | A | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 11/15/2005 at 6:38:16 AM. Contact: ###-####. cor. fee due posted called 110.3(A) shall use manufactures listed equip grd kit per instructions, replace cut and damaged neutral bus,110.14 shall use splicing devices identified for cu/al, 250.8 shall not use SMS for grds or bonds, 680.26 bond all metal with 5 ft of spa to spa equip, seal unused openings
|
Final | 10/10/2003 | 10/10/2003 | 10/10/2003 | P | FAIL |
Jack Frank
|
|
|
MR or MRS Blair; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
cor. posted called 110.3(B) all wiring shall be #6 copper bond all metal, and provide clearence speakers and wiring spa only listed for canada, 250.140&142 needs 4 wire to range and dryer from sub panel 10/10/2003 3:24:37 PM
|
Permanent Service | 2/21/2003 | 2/24/2003 | 2/24/2003 | A | NR |
Jack Frank
|
|
|
rowdy ###-#### will be ready in the PM 2/24/2003 9:44:34 AM
|
Permanent Service | 2/24/2003 | 2/24/2003 | 2/24/2003 | P | PASS |
Jack Frank
|
|
|
###-####
p/s u/g rec. ok 2/24/2003 12:15:17 PM
|