Final | 11/19/2003 | 11/19/2003 | 11/19/2003 | P | PASS |
Jack Frank
|
|
|
Gordon --- call for access.; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes needs to added recept for counter space right of sink met with contractor he will correct and call me when complete 11/19/2003 2:20:58 PM
|
Electrical Rough-In | 7/9/2003 | 7/9/2003 | 7/9/2003 | P | PASS |
Jim Schmer
|
|
|
GORDON ###-#### RE-INSP
|
Electrical Rough-In | 7/8/2003 | 7/8/2003 | 7/8/2003 | P | FAIL |
Jack Frank
|
|
|
after 2 please ###-#### gordon cor. and do not cover posted met with contractor 210.52(B&C) family rm and liviing rm on small appliance branch circuit, 250.148 tie all grds together in boxes 334.112 use type NM-B cable he use some type MN old stuff not 90 degree C rated 7/8/2003 4:34:01 PM
|