Final | 9/24/2003 | 9/25/2003 | 9/25/2003 | A | FAIL |
Pat Lass
|
|
|
Please contact Mark Bridgewater for the inspection at ###-#### on Thursday morning Septemer 25, 2003.; Phone #: ###-#### Internet Inspection Request from: chris green
mast support 9/25/2003 10:58:05 AM
|
Final | 9/25/2003 | 9/25/2003 | 9/25/2003 | P | PASS |
Pat Lass
|
|
|
PLEASE REINSPECT TODAY,9-25, GUYWIRE HAS BEEN MOVED. CONTACT MARK BRIDGEWATER AT ###-####; Phone #: ###-#### Internet Inspection Request from: chris green
|
Electrical Rough-In | 9/18/2003 | 9/19/2003 | 9/19/2003 | A | PASS |
Pat Lass
|
|
|
Please do an electrical rough-in inspection on the back porch wall on Friday 9/19/03 in the early a.m.; Phone #: ###-#### Internet Inspection Request from: chris green
|
Electrical Rough-In | 9/16/2003 | 9/17/2003 | 9/17/2003 | A | PASS |
Jim Schmer
|
|
|
Service Grounding Inspection-contact bldr Mark Bridgewater at ###-####.; Phone #: ###-#### Internet Inspection Request from: chris green p/s o/h rec - ok 9/17/2003 9:31:48 AM
|
Electrical Rough-In | 9/10/2003 | 9/11/2003 | 9/11/2003 | A | PASS |
Jim Schmer
|
|
|
Please reinspect for electrical rough-in on Thursday morning 9/11/03 by 9:00am. Corrections have been made. Thank you.; Phone #: ###-#### Internet Inspection Request from: chris green
|
Electrical Rough-In | 9/9/2003 | 9/10/2003 | 9/10/2003 | A | FAIL |
Pat Lass
|
|
|
Please do inspection by 10:00 am; Phone #: ###-#### Internet Inspection Request from: chris green300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points.
250.148 Continuity and Attachment of Equipment Grounding Conductors to Boxes.
(A) Metal Boxes. A connection shall be made between the one or more equipment grounding conductors and a metal box
314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies.
Boxes and conduit bodies shall be of sufficient size to provide free space for all enclosed conductors.
230.28 Service Masts as Supports.
Where a service mast is used for the support of service-drop conductors, it shall be of adequate strength or be supported by braces or guys to withstand safely the strain imposed by the service drop.
Boise City and Idaho Power require support within 30" of a weather head and 2" IMC or RMC when used as a mast for support.
300.4 Protection Against Physical Damage.
Where subject to physical damage, conductors shall be adequately protected.
(D) Cables and Raceways Parallel to Framing Members.
314.17 Conductors Entering Boxes, Conduit Bodies, or Fittings.
Conductors entering boxes, conduit bodies, or fittings shall be protected from abrasion and shall comply with 314.17(A) through (D).
(C) Nonmetallic Boxes and Conduit Bodies. Nonmetallic boxes and conduit bodies shall be suitable for the lowest temperature-rated conductor entering the box. Where nonmetallic boxes and conduit bodies are used with open wiring or concealed knob-
and-tube wiring, the conductors shall enter the box through individual holes. Where flexible tubing is used to enclose the conductors, the tubing shall extend from the last insulating support to not less than 6 mm (1/4 in.) inside the box and beyond any cable clamp. Where nonmetallic-sheathed cable or multiconductor Type UF cable is used, the sheath shall extend not less than 6 mm (1/4 in.) inside the box and beyond any cable clamp. In all instances, all permitted wiring methods shall be secured to the boxes.
9/10/2003 9:10:03 AM
|
Electrical Rough-In | 9/4/2003 | 9/5/2003 | 9/5/2003 | A | NR |
Pat Lass
|
|
|
Requesting rough-in to cover on basement walls. Please contact Dave Green ###-#### if questions arise.; Phone #: ###-#### Internet Inspection Request from: chris green
n 9/5/2003 9:00:48 AM
|
Permanent Service | 8/19/2003 | 8/20/2003 | 8/20/2003 | P | CANC |
Pat Lass
|
|
|
|
Permanent Service | 8/19/2003 | 8/20/2003 | 8/20/2003 | A | NR |
Pat Lass
|
|
|
|
Final | 8/19/2003 | 8/19/2003 | 8/19/2003 | P | NR |
Pat Lass
|
|
|
please schedule inspection between 1 or 2 p.m. thanx.; Phone #: ###-#### Internet Inspection Request from: chris green
|