Final | 4/20/2004 | 4/21/2004 | 4/21/2004 | A | PASS |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 4/20/2004 at 9:36:17 AM. Contact: ###-####. ok final 4/21/2004 9:15:11 AM
|
Final | 4/5/2004 | 4/5/2004 | 4/5/2004 | P | PART |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 4/5/2004 at 7:46:16 AM. Contact: ###-####. temp ok card signed 4/5/2004 9:39:52 AM
|
Final | 4/2/2004 | 4/2/2004 | 4/2/2004 | P | NR |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 4/2/2004 at 11:26:13 AM. Contact: ###-####. work not completed 4/2/2004 4:07:39 PM
|
Electrical Rough-In | 4/1/2004 | 4/1/2004 | 4/1/2004 | P | PASS |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 4/1/2004 at 9:51:11 AM. Contact: ###-####. ok cover ceiling in tanning area 4/1/2004 2:46:56 PM
|
Electrical Rough-In | 3/10/2004 | 3/10/2004 | 3/10/2004 | P | PASS |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 3/10/2004 at 10:36:24 AM. Contact: ###-####. ok cover walls in tanning rms only 3/10/2004 4:33:16 PM
|
Final | 3/5/2004 | 3/5/2004 | 3/6/2004 | P | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 3/5/2004 at 10:20:20 AM. Contact: ###-####. temp occ. except for tanning booth area 3/7/2004 5:08:45 PM
|
Final | 3/4/2004 | 3/5/2004 | 3/5/2004 | A | NR |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 3/4/2004 at 9:13:04 AM. Contact: ###-####. not ready 3/5/2004 11:59:15 AM
|
Electrical Rough-In | 3/1/2004 | 3/1/2004 | 3/1/2004 | P | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 3/1/2004 at 9:04:15 AM. Contact: ###-####. north side tanning booth area 3/1/2004 3:24:47 PM
|
Electrical Rough-In | 2/27/2004 | 2/27/2004 | 2/27/2004 | P | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 2/27/2004 at 8:15:01 AM. Contact: ###-####. conf with electrician regarding floor boxes 2/27/2004 4:22:32 PM
|
Electrical Rough-In | 2/25/2004 | 2/26/2004 | 2/26/2004 | A | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 2/25/2004 at 11:56:07 AM. Contact: ###-####. part ok cover ceilings day care, conf.rm, staff rm, mgr offs, trainers rm, sales rm,& spinning rm 2/26/2004 9:37:53 AM
|
Electrical Rough-In | 2/24/2004 | 2/24/2004 | 2/24/2004 | P | PASS |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 2/24/2004 at 11:25:25 AM. Contact: ###-####. ok cover south west 2nd floor corner walls 2/24/2004 1:07:14 PM
|
Electrical Rough-In | 2/23/2004 | 2/23/2004 | 2/23/2004 | P | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 2/23/2004 at 8:45:27 AM. Contact: ###-####. ok cover ceiling under stairs 2/23/2004 1:15:43 PM
|
Electrical Rough-In | 2/19/2004 | 2/19/2004 | 2/19/2004 | P | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 2/19/2004 at 8:12:05 AM. Contact: ###-####. ok cover part walls 2/19/2004 3:18:29 PM
|
Electrical Rough-In | 2/13/2004 | 2/17/2004 | 2/17/2004 | A | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 2/13/2004 at 9:06:28 AM. Contact: ###-####. cor. posted met contractor 110.3(B) & 12(A) use, remove or seal unused openings in duplex cable connectors, 352. 26 over 360 degrees of bend , 400.8 no cords above , or through ceilings 300.15(C) needs bushings ends of conduits for low voltage
cor. posted for low voltage shall not use ceiling support wires and support all cables 2/17/2004 9:41:30 AM
|
Electrical Rough-In | 1/29/2004 | 1/29/2004 | 1/29/2004 | P | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 1/29/2004 at 8:08:21 AM. Contact: ###-####. ok cover walls & ceilings marked on print 1/29/2004 4:09:12 PM
|
Electrical Rough-In | 1/23/2004 | 1/26/2004 | 1/26/2004 | A | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 1/23/2004 at 1:14:48 PM. Contact: ###-####. ok cover ext walls east & south side of pool 1/26/2004 8:47:02 AM
|
Electrical Rough-In | 1/20/2004 | 1/21/2004 | 1/21/2004 | A | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 1/20/2004 at 9:39:45 AM. Contact: ###-####. ok cover floor tanning booth area slab conduit 1/21/2004 9:47:30 AM
|
Electrical Rough-In | 1/9/2004 | 1/9/2004 | 1/9/2004 | P | PART |
Mike Kinnear
|
|
|
Jim; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes ok cover part walls south side by pool 1/9/2004 4:00:49 PM
|