Final | 6/22/2004 | 6/23/2004 | 6/23/2004 | A | FAIL |
Pat Lass
|
|
|
brandon; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
352.30 secure and support conduit 6/23/2004 9:40:28 AM
|
Final | 6/16/2004 | 6/17/2004 | 6/17/2004 | A | FAIL |
William E Thomas
|
|
|
bradon; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
680.42.A.1 liquidtite flex shall not excede 6' in length 6/17/2004 3:13:24 PM . 6/17/2004 3:13:28 PM
|
Permanent Service | 6/8/2004 | 6/8/2004 | 6/8/2004 | P | PART |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 6/8/2004 at 10:15:31 AM. Contact: ###-####.
P/S O/H R Ok
Hot tub not listed and required gfci recep not yet installed.
liquid tight flex is not properly installed. 6/8/2004 2:41:24 PM
|
Permanent Service | 6/7/2004 | 6/7/2004 | 6/7/2004 | P | NR |
Pat Lass
|
|
|
###-#### brandon
had conf. COW unlisted hot tub in front of new service most everything requires reworking lots of old illeagle installations probablly caused old service to burn up. 6/7/2004 3:28:06 PM
|