Permit Information
Permit NumberELE04-01761
StatusFinaled
Name J-KEL INC
Site Address 1713 S GRANT AVE
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Electrical Rough-In8/16/20048/16/20048/16/2004PPASS
DetailsJim Schmer
Final8/16/20048/16/20048/16/2004PPASS
DetailsJim Schmer
Final8/16/20048/16/20048/16/2004PFAIL
DetailsMike Kinnear
jim; Phone #: ###-#### Internet Inspection Request from: Annette Moore fail corrections nec 210.70(A)(3), switched light in equipment rm & nec 210.52(C)(1) outlt spacing kit. over 48 inchs ( gave contractor survey regarding this) 8/16/2004 1:00:36 PM
Final8/16/20048/16/20048/16/2004PCANC
DetailsJim Schmer
Permanent Service8/2/20048/2/20048/2/2004PPASS
DetailsJack Frank
p/s o/h new ok
Electrical Rough-In6/24/20046/24/20046/24/2004PPASS
DetailsMike Kinnear
also underground--jim; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok cover ri house & garage ok cover under ground conduit note survey kit counter spacing for outlets 6/24/2004 2:53:43 PM
Permanent Service6/23/20046/23/20046/23/2004APASS
DetailsJack Frank
p/s o/h new ok
Rough-In Permanent Service6/22/20046/23/20046/23/2004AFAIL
DetailsJack Frank
JIM; Phone #: ###-#### Internet Inspection Request from: Annette Moore see added p/s
cor. not made still needs to correct 6" free conductor and make up called 6/23/2004 8:03:09 AM
Electrical Rough-In6/22/20046/22/20046/22/2004PFAIL
DetailsJack Frank
jim; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles met contractor 300.4 11/4", 300.14 short wires,, 3116 box fill, remove range from kit. circuit, access from outside too GEC acorn clamp 6/22/2004 1:55:59 PM