Final | 2/2/2007 | 2/2/2007 | 2/2/2007 | P | PASS |
Bob Reichert
|
|
|
see aging for description for final
|
ELE-Aging Inspection | 2/2/2007 | 2/2/2007 | 2/2/2007 | P | PASS |
Bob Reichert
|
|
|
talked with J Storey, reviewed permits and activities, this permit should be final, since contr came and fixed and he had permit that was finalled by 432. ok to final
|
Electrical Rough-In | 6/29/2006 | 7/3/2006 | 7/3/2006 | A | FAIL |
Mike Kinnear
|
|
|
ladonna; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley got permits fixed. note not all correction completed. t/w 324 told him i would do the inspections. this was more for conf. note please send inspections to 412.
|
Electrical Rough-In | 5/30/2006 | 5/31/2006 | 5/31/2006 | A | FAIL |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung corr. met owner 300.14, 300.4 nail plates and 11/4", 314.16 box fill steel cutins, bath rm shall be on own 20 amp circuit 210.52(D),11(C)(3),23(A)(2) 250.148 grd metal boxes, 404.9 grd switches, 110.3 use approved tool for crimp devices note if corr. not made or more violations created permit will be voided also shall complete trim out and final for basement and outside lights by driveway
|
Conference | 10/28/2005 | 10/28/2005 | 10/28/2005 | A | PART |
Jack Frank
|
|
|
01 ok
|
Conference | 7/6/2005 | 7/7/2005 | 7/7/2005 | A | PASS |
Mike Kinnear
|
|
|
ladona; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie conf regard burial wire depth 18 inch
|