Final | 2/25/2005 | 2/25/2005 | 2/25/2005 | P | PASS |
Pat Lass
|
|
|
dave; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
Rough-In Permanent Service | 2/22/2005 | 2/22/2005 | 2/22/2005 | P | FAIL |
Pat Lass
|
|
|
David; Phone #: ###-#### Internet Inspection Request from: Jan Rice
GFCI protect outside receps.
location of closet light.
counter top recep required above counter. 2/22/2005 3:30:20 PM
|
Electrical Rough-In | 9/23/2004 | 9/24/2004 | 9/24/2004 | A | PASS |
Jim Schmer
|
|
|
dave; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie (NOTE: grds & Neut. seperated in sub-panel) 9/24/2004 9:19:20 AM
|
Electrical Rough-In | 9/21/2004 | 9/21/2004 | 9/21/2004 | P | FAIL |
Jack Frank
|
|
|
dave; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie cor. posted called 300.4 nail plates and 1 1/4", 314.16 , 314.20 outside boxes, 314.43 no screws in plastic boxes, 334.30, 314.17(C) staple within 8" of boxes, address subpanel isolate grds and neuts cow 9/21/2004 1:46:46 PM
|