Final | 11/18/2005 | 11/21/2005 | 11/21/2005 | A | PASS |
Pat Lass
|
|
|
CONTACT: MARK ROBINSON; Phone #: ###-#### Internet Inspection Request from: Deb McCoy no card
|
Final | 11/15/2005 | 11/16/2005 | 11/16/2005 | A | NR |
Pat Lass
|
|
|
CONTACT: MARK ROBINSON; Phone #: ###-#### Internet Inspection Request from: Deb McCoy kitchen recep not working. dinning room counter receps not installed. closet light not moved. directory incomplete.
|
Final | 11/1/2005 | 11/2/2005 | 11/2/2005 | P | FAIL |
Pat Lass
|
|
|
Contact: Mark Robinson; Phone #: ###-#### Internet Inspection Request from: Deb McCoy outlet required for peninsular counter in kitchen. GFCI protect receps within 6 ft of wet bar and kitchen counter. grounding of service to house. install cover opposite entry on wireway under panels. closet light locations. switch in front portch weatherproof. 406.4(e) receps face up from counter in dinningroom. secure romex behind com cabinet. coverplate to rest on wall surface in dinningroom
|
Permanent Service | 6/14/2005 | 6/15/2005 | 6/15/2005 | P | PASS |
Pat Lass
|
|
|
###-#### Please call Mark Robinson if you have any questions.; Phone #: ###-#### Internet Inspection Request from: Shelli Daylong P/S U/g R Ok
|
Electrical Rough-In | 5/5/2005 | 5/6/2005 | 5/6/2005 | P | PART |
Pat Lass
|
|
|
###-#### CONTACT: MARK ROBINSON - LATE AFTERNOON (3:00 OR 4:00) INSP. PLS INSP FOR GARAGE & KITCHEN; Phone #: ###-#### Internet Inspection Request from: Deb McCoy 5/6/2005 7:40:35 AM
garage and kitchen ok 5/6/2005 1:31:18 PM
|
Electrical Rough-In | 4/27/2005 | 4/28/2005 | 4/28/2005 | P | PASS |
Pat Lass
|
|
|
###-#### Contact: Mark Robinson Basement Rough-in inspection; Phone #: ###-#### Internet Inspection Request from: Deb McCoy 4/28/2005 11:50:02 AM
|
Electrical Rough-In | 4/18/2005 | 4/18/2005 | 4/18/2005 | P | PART |
Pat Lass
|
|
|
CONTACT: MARK ROBINSON ; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
U/G for Service and feeders ok 4/18/2005 2:42:12 PM
|
Electrical Rough-In | 4/6/2005 | 4/6/2005 | 4/6/2005 | P | PART |
Pat Lass
|
|
|
CONTACT: MARC ROBINSON; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
all but kitchen and basement ok 4/6/2005 2:55:59 PM
|
Electrical Rough-In | 3/14/2005 | 3/16/2005 | 3/16/2005 | A | NR |
Pat Lass
|
|
|
contact: Mark Robinson; Phone #: ###-#### Internet Inspection Request from: Shelli Daylong
had conf about box fill protection of conductors and have to open area for inspection 3/16/2005 9:38:11 AM
|
Electrical Rough-In | 12/17/2004 | 12/17/2004 | 12/17/2004 | P | PART |
William E Thomas
|
|
|
CONTACT: SHANE KORTE - FRONT PORCH CEILING INSPECTION.; Phone #: ###-#### Internet Inspection Request from: Deb McCoy
front porch cieling ok 12/17/2004 5:59:35 PM
|