Permit Information
Permit NumberELE05-00027
StatusFinaled
Name C H ELECTRIC
Site Address 724 N TROUTNER WAY
Project NameNorthridge Sub No.5
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final5/9/20055/9/20055/9/2005PPASS
DetailsPat Lass
chris; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
Final5/6/20055/6/20055/6/2005PFAIL
DetailsPat Lass
chris; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
Box on island counter shall match wiring method.
Fanlight in shower is required to be GFCI protected.
Fan in green bedroom not wired properly.
5/6/2005 3:01:12 PM
Electrical Rough-In1/13/20051/14/20051/14/2005APASS
DetailsPat Lass
CHRIS; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
Permanent Service1/14/20051/14/20051/14/2005APASS
DetailsPat Lass
P/S U/g N Ok
Rough-In Permanent Service1/4/20051/4/20051/4/2005PFAIL
DetailsJack Frank
chris ###-#### cor. posted called 250.148 splice all grds together 2 gang box kit., 300.14 all boxes, 210.52(A) outlets by entertainment center upstairs rec. rm. they changed from what the plans show, 210.52(C) remove power from small appliance branch circuit that feeds low voltage cabinet under stairs room is formal dinning rm 1/4/2005 3:55:44 PM