Permit Information
Permit NumberELE05-00028
StatusFinaled
Name JACK'S ELECTRIC
Site Address 1406 N 11TH ST
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/30/20053/30/20053/30/2005PPASS
DetailsPat Lass
jack; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
NO CARD 3/30/2005 2:41:12 PM
Final3/25/20053/25/20053/25/2005PFAIL
DetailsPat Lass
jack; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
GFCI protect bathroom receps
lock out for hard wired oven 3/25/2005 2:00:16 PM
Final3/21/20053/21/20053/21/2005PFAIL
DetailsBob Reichert
jack; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, left correction notice, 314.15(A) emt connectors and fittings shall be listed for wet locations, 408.4 panel schedule shall have details, 406.5 recepts shall have faceplate, 406.2 range recpt shall be provided,210.11(C)(2) laundry recpt shall work, 210.70(A)(2)(b) light shall work at garage, 300.5 shall uncover u/g to garage to verify depth of wiring. 3/21/2005 2:29:48 PM
Electrical Rough-In1/11/20051/12/20051/12/2005APASS
DetailsPat Lass
Jack-call before you go so he can let you in; Phone #: ###-#### Internet Inspection Request from: Jan Rice
Electrical Rough-In1/10/20051/11/20051/11/2005PFAIL
DetailsJack Frank
please call half hour prior to inspection so he can let ya in///jack; Phone #: ###-#### Internet Inspection Request from: Barbara Moore cor. posted met contractor 300.4(A)(1)&(D), 210.52(C)(1) countertop outlet spacing, 210.52(D)&210.11(C)(3) outlet within 3ft of sink,and 20 amp bath circuit, 250.140 shall use SE type cable from P/S or 10/3 romex for cook top 1/11/2005 2:09:46 PM