Final | 5/16/2005 | 5/17/2005 | 5/17/2005 | A | PASS |
Pat Lass
|
|
|
Phone #: ###-#### Internet Inspection Request from: Corrie Hall no card
|
Final | 5/16/2005 | 5/16/2005 | 5/17/2005 | P | FAIL |
Pat Lass
|
|
|
cody; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles gfci in bath and laundry, label panel directory, install closet fixture or remove wiring
|
Electrical Rough-In | 2/8/2005 | 2/8/2005 | 2/8/2005 | P | PASS |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 2/8/2005 at 10:46:42 AM. Contact: ###-####.
|
Permanent Service | 2/8/2005 | 2/8/2005 | 2/8/2005 | P | PASS |
Pat Lass
|
|
|
P/S U/G N Ok
|
Electrical Rough-In | 1/27/2005 | 1/28/2005 | 1/28/2005 | A | FAIL |
Bob Reichert
|
|
|
steve; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles 314.43 Plastic box shall not use screws inside, 300.4(D) NM cable shall be 11/4" from edge of framing members, 210.52(B)(2) small appliance branch circuits shall not have other outlets, BCC all make-up shall be done (metal box, vac, fireplace,tub) Called contr and left message. 1/28/2005 9:40:38 AM
|