Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberELE05-00335
StatusFinaled
Name DENNIS TOLAN
Site Address 3030 N ASH PARK LN
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/2/20056/2/20056/2/2005PPASS
DetailsBob Reichert
dennis; Phone #: ###-#### Note: please ring the doorbell a couple times-he will be asleep Internet Inspection Request from: Cathy Chiles corrections made, ok to final
Final6/1/20056/1/20056/1/2005PFAIL
DetailsJack Frank
dennis; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa cor.posted met owner 314.20 boxes shall be flush with combustible material, 410.8 (A&B) enclosed type fixture no pendents allowed MB closet, 210.12 arc fault all circuits in M bed
Electrical Rough-In2/4/20052/7/20052/7/2005APASS
DetailsBob Reichert
dennis; Phone #: ###-#### Internet Inspection Request from: Barbara Moore corrections made, ric ok 2/7/2005 9:45:45 AM
Electrical Rough-In2/2/20052/3/20052/3/2005AFAIL
DetailsBob Reichert
Dennis; Phone #: ###-#### Internet Inspection Request from: Jan Rice Bcc all wires shall be made up in boxes,314.17 nm cable shall be stapled within 8" of box. 2/3/2005 8:49:51 AM