Final | 5/20/2005 | 5/20/2005 | 5/20/2005 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 5/20/2005 at 6:54:28 AM. Contact: ###-####. ok to final
|
Rough-In Permanent Service | 3/7/2005 | 3/7/2005 | 3/7/2005 | P | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 3/7/2005 at 9:39:44 AM. Contact: ###-####. called contr and left message to use nm cable conn at back lite box, rest of corrections made. ric ok p/s u/g n ok 3/7/2005 12:52:53 PM
|
Rough-In Permanent Service | 2/24/2005 | 2/24/2005 | 2/24/2005 | P | FAIL |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 2/24/2005 at 8:52:51 AM. Contact: ###-####. 110.12(C) internal parts shall not be painted, 314.17(C) nm cable shall be 1/4" inside box, 334.30 nm cable shall be supported within 8" of box, 314.17(A) connector shall be supplied where 1/2" ko used, 300.4(D) nm cable shall be within 1/4" of edge of framing member,BCC shall have approved set of plans on job 2/24/2005 11:59:38 AM
|
Electrical Rough-In | 2/2/2005 | 2/3/2005 | 2/3/2005 | A | CANC |
Bob Reichert
|
|
|
Shaun; Phone #: ###-#### Internet Inspection Request from: Jan Rice Called contractor, No job id, no plans, no address, told him to recall when ready so we are at right place. 2/3/2005 8:09:07 AM
|