Final | 7/28/2005 | 7/29/2005 | 7/29/2005 | A | PASS |
Bob Reichert
|
|
|
reinspection of final; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH corrections made, ok to final
|
Final | 7/27/2005 | 7/28/2005 | 7/28/2005 | A | FAIL |
Bob Reichert
|
|
|
Final inspect on new construction; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH called contr, left corr notice 352.39(A) rnc shall be strapped within 3' of box, 210.8(A)(2) garage recpts shall be gfci protected,210.52(D) recpt shall be within 3' of bath sink
|
Electrical Rough-In | 3/9/2005 | 3/9/2005 | 3/9/2005 | P | PASS |
Bob Reichert
|
|
|
ROUGH IN AND SERVICE INSPECTION. THANK YOU. CAN THIS BE INSPECTED EARLY AFTERNOON. THANK YOU; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ric ok, p/s u/g n ok 3/9/2005 2:25:26 PM
|