Final | 2/13/2006 | 2/13/2006 | 2/13/2006 | P | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 2/13/2006 at 6:29:49 AM. Contact: (208) ok
|
Final | 2/10/2006 | 2/10/2006 | 2/10/2006 | P | FAIL |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 2/10/2006 at 6:52:14 AM. Contact: ###-####. GFCI protection within 6 ft. of a sink
|
Electrical Rough-In | 8/11/2005 | 8/11/2005 | 8/11/2005 | P | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 8/11/2005 at 9:17:42 AM. Contact: (208) r/i ok
|
Conference | 7/26/2005 | 7/26/2005 | 7/26/2005 | P | CANC |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 7/26/2005 at 7:36:27 AM. Contact: ###-####. no conference they wanted a r/i, see added r/i
|
Electrical Rough-In | 7/26/2005 | 7/26/2005 | 7/26/2005 | P | FAIL |
Jack Frank
|
|
|
cor. posted met owner 314.17&110.3 replace cutin boxes broken clamps, and sheath shall extent 1/4" into box, 300.4 11/4" and nail plates, 300.14 6" free length, 314,16 box fill
|
Conference | 7/20/2005 | 7/20/2005 | 7/20/2005 | P | NH |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 7/20/2005 at 6:29:10 AM. Contact: ###-####. notice posted called got someone at her work place
|
Electrical Rough-In | 3/30/2005 | 3/30/2005 | 3/30/2005 | P | FAIL |
Jack Frank
|
|
|
cor. posted 210.52(A) shall provide required outlet spacing for downstairs bed remodel, and new room added above garage, shall expose, or remove all wiring done by owner without inspection, note need approved plans at job site 3/30/2005 2:39:02 PM
|