Final | 8/9/2005 | 8/9/2005 | 8/9/2005 | P | PASS |
Pat Lass
|
|
|
chad; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
|
Final | 8/8/2005 | 8/9/2005 | 8/9/2005 | A | FAIL |
Pat Lass
|
|
|
chad; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ground main disconnect move closet lights in master closet protect romex in basement install receps in master bath
|
Permanent Service | 8/2/2005 | 8/3/2005 | 8/3/2005 | A | PASS |
Pat Lass
|
|
|
###-#### - chad this is for garage service and pvc to be burried P/S O/h N Ok
|
Final | 8/2/2005 | 8/3/2005 | 8/3/2005 | A | CANC |
Pat Lass
|
|
|
please call for access///chad; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa per chad 8/2/2005
|
Electrical Rough-In | 4/25/2005 | 4/25/2005 | 4/25/2005 | P | PASS |
Pat Lass
|
|
|
chad; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
Rough-In Permanent Service | 4/21/2005 | 4/22/2005 | 4/22/2005 | A | FAIL |
Bob Reichert
|
|
|
chad ###-#### called, left message, service not ready, no grounding, 300.4(A)(1)&(D) shall provide nail plates and 1 1/4" all areas from inside and outside of framing members, 21.52(A)(2) wall space by front door shall have recpt, 314.3 nonmetallic boxes shall be listed to be used with metal raceways, 314.20 boxes shall be flush with finished surface, 314.17 openings shall be closed BCC shall have approved set of plans on job and job ID sticker 4/22/2005 9:56:50 AM
|