Permit Information
Permit NumberELE05-01560
StatusFinaled
Name RACE ELECTRIC
Site Address 1624 S VERMONT AVE
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/7/20057/8/20057/8/2005APASS
DetailsMike Kinnear
Phone #: ###-#### Internet Inspection Request from: KATHY WEIL ok final correction made
Final6/29/20056/30/20056/30/2005AFAIL
DetailsBob Reichert
Call Rob if this fails at ###-####; Phone #: ###-#### Internet Inspection Request from: KATHY WEIL called contr, left corr notice, 406.5,404.9 faceplates shall cover openings and seat against mounting surface,408.4 circuit directory shall be specific, 110.26(A)(2) panel shall have 30" wide work space, 422.16(B)(1)(2) disposal cord shall be max 3' long,210.8(A)(3) outdoor recpts shall be gfci, 314.21 sheetrock shall be repaired in util room for light, 210.70(A)(2)(a) light shall be in stairway
Electrical Rough-In5/9/20055/9/20055/9/2005PPASS
DetailsMike Kinnear
kathy; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok cover underground conduit
Permanent Service5/9/20055/9/20055/9/2005PPASS
DetailsMike Kinnear
kathy; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
p/s u/g n ok
Electrical Rough-In5/5/20055/6/20055/6/2005APASS
DetailsPat Lass
cathy; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa
R/I Ok
service not ready 5/6/2005 9:05:02 AM
Electrical Rough-In5/4/20055/5/20055/5/2005ANR
DetailsMike Kinnear
###-#### cathy conf with contractor