Final | 6/28/2006 | 6/29/2006 | 6/30/2006 | A | PASS |
Jack Frank
|
|
|
Per Jim Schmer 8:15 Internet Inspection Request from: Rita DeYoung
|
Final | 6/28/2006 | 6/28/2006 | 6/28/2006 | P | CANC |
Jim Schmer
|
|
|
All corrections are done. Ready for final inspection. Internet Inspection Request from: Latisha Peltier reschedual for friday am so he can be there. JMS
|
Final | 6/27/2006 | 6/27/2006 | 6/27/2006 | P | CANC |
Jack Frank
|
|
|
Apt. #17 - changed panel to accommodate circuits. Internet Inspection Request from: Latisha Peltier see added r/i for subpanel
|
Electrical Rough-In | 6/27/2006 | 6/27/2006 | 6/27/2006 | P | PASS |
Jack Frank
|
|
|
Apt. #17 - changed panel to accommodate circuits. Internet Inspection Request from: Latisha Peltier panel ok no final
|
Final | 6/15/2006 | 6/15/2006 | 6/15/2006 | A | FAIL |
Pat Lass
|
|
|
Internet Inspection Request from: Latisha Peltier all units require corrections for directories. unit 17 lock out for heaters units 11 and 15 bath receps not working
|
Final | 6/6/2006 | 6/6/2006 | 6/6/2006 | P | NR |
Pat Lass
|
|
|
Corrections done that Jack Frank requested. Please re-inspect final. Please send Jack if possible. Internet Inspection Request from: Latisha Peltier no numbers on appartments so I can't keep track of where violations are. hood fan wires are live and not in a box and hood fans are not hooked up. inspection is for appartments 9 through 17
|
Final | 6/6/2006 | 6/6/2006 | 6/6/2006 | A | NH |
Pat Lass
|
|
|
Internet Inspection Request from: Latisha Peltier no contact number called and didnot get response for 2 hrs
|
Final | 6/5/2006 | 6/5/2006 | 6/5/2006 | P | NH |
William E Thomas
|
|
|
Internet Inspection Request from: Latisha Peltier no access, called contractor for him to re-schedule
|
Final | 5/26/2006 | 5/30/2006 | 5/30/2006 | A | FAIL |
Jack Frank
|
|
|
Internet Inspection Request from: Latisha Peltier called 314.20 needs box extensions where boxes are not flush with combustible material, 408.4 panel schedules not correct, 210.12 needs afci for bed rms not gfci called contractor will correct and reschedule
|
ELE-Aging Inspection | 5/22/2006 | 5/22/2006 | 5/24/2006 | | NR |
Pat Lass
|
|
|
suc
|
ELE-Aging Inspection | 3/21/2006 | 3/21/2006 | 3/21/2006 | | NR |
Pat Lass
|
|
|
Job seems to be at a standstill called contractor and got no response address also seems to be wrong. 512, 514, 516
|
ELE-Aging Inspection | 1/16/2006 | 1/16/2006 | 1/20/2006 | | NR |
Pat Lass
|
|
|
suc
|
ELE-Aging Inspection | 11/14/2005 | 11/14/2005 | 11/15/2005 | | NR |
Pat Lass
|
|
|
suc
|
Rough-In Permanent Service | 9/12/2005 | 9/12/2005 | 9/12/2005 | P | PART |
Jack Frank
|
|
|
Rough-in inspection on apartments 9, 10, 11, 12 & 17. ; Phone #: ###-#### Internet Inspection Request from: Latisha Peltier r/i ok no p/s
|
Rough-In Permanent Service | 9/7/2005 | 9/7/2005 | 9/7/2005 | P | PASS |
Mike Kinnear
|
|
|
Inspection of apartments 1,2,3 & 4. Blueprints are on site as requested by inspector.; Phone #: ###-#### Internet Inspection Request from: Latisha Peltier ok cover ri units 13, 14, 15, & 16 note no wires pulled to sub panals need to inspect them at final.
|
Rough-In Permanent Service | 8/25/2005 | 8/26/2005 | 8/26/2005 | A | NR |
William E Thomas
|
|
|
Re-inspection of apts. 1,2,3 & 4. Internet Inspection Request from: Latisha Peltier still no prints for the job
|
Rough-In Permanent Service | 8/18/2005 | 8/19/2005 | 8/19/2005 | A | NR |
Pat Lass
|
|
|
Please inspect apartments 1,2,3 & 4.; Phone #: ###-#### Internet Inspection Request from: Latisha Peltier called contractor and will set up conf next week. no print
|
Permanent Service | 7/25/2005 | 7/25/2005 | 7/25/2005 | A | PASS |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 7/25/2005 at 6:12:08 AM. Contact: ###-####. service has already been passed and meters can be set
|
Rough-In Permanent Service | 7/11/2005 | 7/11/2005 | 7/11/2005 | A | PART |
William E Thomas
|
|
|
Scheduled by a contractor via Hello! on 7/11/2005 at 6:29:44 AM. Contact: ###-####. p/s o/h n/r ok
|
Permanent Service | 6/20/2005 | 6/21/2005 | 6/21/2005 | A | CANC |
Bob Reichert
|
|
|
please call prior to inspection so he can meet ya there///###-#### shawn was for conf
|
Conference | 6/21/2005 | 6/21/2005 | 6/21/2005 | A | DONE |
Bob Reichert
|
|
|
please call prior to inspection so he can meet ya there///###-#### met with elect to talk about service
|