Permit Information
Permit NumberELE05-02885
StatusFinaled
Name POWERTECH ELECTRIC, LLC
Site Address 4008 W GROVER ST
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - Addition: outlets
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/28/20059/29/20059/29/2005PPASS
DetailsJack Frank
Phone #: ###-#### Internet Inspection Request from: Randy Fletcher ok card signed
Electrical Rough-In8/25/20058/26/20058/26/2005APASS
DetailsJack Frank
Phone #: ###-#### Internet Inspection Request from: Randy Fletcher ok
Electrical Rough-In8/25/20058/25/20058/25/2005PFAIL
DetailsWilliam E Thomas
Phone #: ###-#### Internet Inspection Request from: Randy Fletcher
1. needs two grounrods-they updated the system and only put one rod in
2. stapleing/securing of romex
Final8/19/20058/22/20058/22/2005PFAIL
DetailsJack Frank
Phone #: ###-#### Internet Inspection Request from: Randy Fletcher this is for r/i not final, cor. posted called left message 314. 17 replace 2 gang box broken clamp, 210.52(A) 2ft wall, 6ft 12ft,210.12 arc fault all circuits in bed rm, 310.16 protect #14 at 15 amps , shall not feed bed rm from laundry circuit, 300.4(A)(1)&(D)