Final | 3/15/2006 | 3/15/2006 | 3/15/2006 | P | PASS |
William E Thomas
|
|
|
Robert ###-#### for ele final; 10-17-05 ele final must have been an error per inspector Bill Thomas, therefore reschedule 3-15-06 eus
|
Final | 10/17/2005 | 10/17/2005 | 10/17/2005 | P | PASS |
William E Thomas
|
|
|
final ok
|
Electrical Rough-In | 9/15/2005 | 9/16/2005 | 9/16/2005 | A | PASS |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 9/15/2005 at 6:17:24 PM. Contact: ###-####.
|
Permanent Service | 9/16/2005 | 9/16/2005 | 9/16/2005 | P | PASS |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 9/15/2005 at 6:17:24 PM. Contact: ###-####. P/S U/G N Ok done by Bob
|
Rough-In Permanent Service | 9/15/2005 | 9/15/2005 | 9/15/2005 | P | FAIL |
Bob Reichert
|
|
|
doug ###-#### called contr, left corr notice, 300.4(D) 1 1/4" shall be maintained from edge of framing member, 110.12(C) nm cable jacketing shall not be cut, 210.52(H) hall over 10' shall have recpt, 210.52(A)(1)&(2) basement room shall have recpt in 2' wall and not over 12'
|