Final | 12/2/2005 | 12/5/2005 | 12/5/2005 | A | PASS |
Jack Frank
|
|
|
OUTDOOR FAN INFO ON WET BAR NEXT TO SINK, GARAGE CODE IS (1296 ENTER); Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack
|
Final | 12/2/2005 | 12/2/2005 | 12/2/2005 | P | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 12/2/2005 at 10:50:28 AM. Contact: ###-####. new cor. posted also fee due,called 314.43 remove madison clamp from plastic box, for refer under dinning rm counter 356.42 shall use listed conn. for LNFC, outlet end of peninsular counter
|
Final | 11/30/2005 | 12/1/2005 | 12/1/2005 | A | FAIL |
Jack Frank
|
|
|
garage code is (1296 enter) to get inside; Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack cor. called left message, 210.52(C) outlet on peninsular counter too far under it, needs outlet left of sink on countertop in dinning rm
|
Final | 11/30/2005 | 12/1/2005 | 11/30/2005 | A | CANC |
Jack Frank
|
|
|
garage code is (1296 enter)to get inside; Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack Inspection cancelled from web by: Lee VanSchoiack
|
Rough-In Permanent Service | 9/20/2005 | 9/21/2005 | 9/21/2005 | A | PASS |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack r/i ok p/s u/g new ok
|
Rough-In Permanent Service | 9/20/2005 | 9/20/2005 | 9/20/2005 | P | NR |
Jack Frank
|
|
|
APROX. 3 PM FOR INSPECTION PLEASE; Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack met with contractor
|