Final | 2/20/2006 | 2/21/2006 | 2/21/2006 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 2/20/2006 at 5:13:29 PM. Contact: ###-####. corr made, ok to final
|
Final | 2/7/2006 | 2/7/2006 | 2/7/2006 | P | FAIL |
Bob Reichert
|
|
|
Dan -- call 1st before insp for key access; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong called contr,left corr notice,210.52(H) hallway over 10' shall have receptacle, 406.5 recpt faceplate shall seat against mounting surface(library), 404.4 switch shall not be installed in tub area,440.6(A) min breaker size for a/c shall be 45A, 430.107 pump motor disconnect shall be readily accessible,680.73 electrical equipment for tub shall be accessible without damaging building, 408.4 circuit directory shall be complete and specific for each circuit (identify 2 small appliance branch circuits in kitchen)
|
Electrical Rough-In | 12/22/2005 | 12/22/2005 | 12/22/2005 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 12/22/2005 at 7:10:09 AM. Contact: ###-####. ok to cover floor heat in master bath
|
Rough-In Permanent Service | 10/6/2005 | 10/6/2005 | 10/6/2005 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 10/6/2005 at 6:13:44 AM. Contact: ###-####. corr made, ric ok, p/s u/g n ok
|
Electrical Rough-In | 10/5/2005 | 10/5/2005 | 10/5/2005 | A | FAIL |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 10/5/2005 at 7:23:06 AM. Contact: ###-####. called contr, left corr notice, 312.5 abrasion protection for gec, 250.24(A)(1) gec shall be connected to gnded conductor term or bus, 210.52 recpt shall be on front of dwelling, 110.12(C) there shall be no broken parts, 300.4(A)(1) and (D) 1 1/4" shall be maintained for holes from edge of framing member and nm cable
|