Electrical Rough-In | 12/6/2005 | 12/7/2005 | 12/7/2005 | A | CANC |
Jim Schmer
|
|
|
Scheduled by a contractor via Hello! on 12/6/2005 at 10:23:02 AM. Contact: ###-####. Owner permit voided because the owner doesn't live at residence. JMS
|
Electrical Rough-In | 12/7/2005 | 12/7/2005 | 12/7/2005 | A | NR |
Jack Frank
|
|
|
nr Jim Schmer is checking job if owner is allowed to have permit, not there primary residence move in house and new garage with apartment on second floor
|
Electrical Rough-In | 12/5/2005 | 12/5/2005 | 12/5/2005 | P | FAIL |
Bob Reichert
|
|
|
caren; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles met with owner, left corr notice,334.30 nm cable shall be stapled within 12" of panel and range,312.5 conductors entering enclosures shall be protected from abrasion,gec and outside boxes, 314.17(C) nm cable jacket shall extend minimum 1/4" inside box,by stairs
|
Conference | 10/27/2005 | 10/27/2005 | 10/27/2005 | P | PART |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 10/27/2005 at 10:48:33 AM. Contact: ###-####.
|