Final | 7/3/2006 | 7/3/2006 | 7/3/2006 | P | PASS |
Mike Kinnear
|
|
|
ok final trim work ele04-02743
|
Final | 12/6/2005 | 12/7/2005 | 12/7/2005 | A | CANC |
Mike Kinnear
|
|
|
Please final on laundry room, stairway light and family room. Panel rated breakers.; Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney wrong type inspection
|
Electrical Rough-In | 12/7/2005 | 12/7/2005 | 12/7/2005 | A | PASS |
Mike Kinnear
|
|
|
Please final on laundry room, stairway light and family room. Panel rated breakers.; Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney ok cover ri
|
Electrical Rough-In | 12/5/2005 | 12/6/2005 | 12/6/2005 | P | NH |
Jack Frank
|
|
|
DOWNSTAIRS FAMILY ROOM, STAIRWAY, & LAUNDRY ROOM. CHANGED BREAKERS IN PANEL TO PANEL RATED BREAKERS.; Phone #: ###-#### notice posted called left # message
|
Rough-In Permanent Service | 10/27/2005 | 10/28/2005 | 10/28/2005 | A | FAIL |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney cor. called 210.52(A) outlet spacing, 314.16 box fill, 210.70(A)(2)(c) fixture and 2 level switching for stairs, 110.3 use manufactures listed breakers olny, 210.12 afci for all circuits in bed rm, 210.52(F)&210.11(C)(2) all outlets inn laundry shall bo on laundry circuit, note remove devices from boxes so I can inspect
|