Electrical Rough-In | 12/14/2006 | 12/15/2006 | 12/15/2006 | A | CANC |
Mike Kinnear
|
|
|
lloyd - note: meter base ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith wrong type inspection
|
Permanent Service | 12/15/2006 | 12/15/2006 | 12/15/2006 | A | PASS |
Mike Kinnear
|
|
|
lloyd - note: meter base ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith p/s o/h reconnect ok
|
Rough-In Permanent Service | 2/27/2006 | 2/28/2006 | 2/28/2006 | P | PART |
Jack Frank
|
|
|
Weston -- for reinspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong r/i ok only, 230.24(A) except #3 mast too low, also bond bushing lug and screw loose
|
Rough-In Permanent Service | 2/22/2006 | 2/23/2006 | 2/23/2006 | A | FAIL |
Pat Lass
|
|
|
Lloyd -- for reinspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong #14 on a 20 A circuit. secure all romex. outer sheath to extend into box for water heater. proper fitting on GEC.
|
Rough-In Permanent Service | 2/1/2006 | 2/2/2006 | 2/2/2006 | A | FAIL |
Jack Frank
|
|
|
requests after 10am please//weston hatch ###-#### please call 15 prior to meet you, if no answer said he will be at the house already cor. do not cover posted met owner 230.28 guy for mast, also meter too high,210.11 c 3 bath rm shall feed only bath rm, 300.10 314.22 bond flex and metal on WH plastic box or do it another way,300.4 nail plates 11/4" everywhere, 314.16 box fill everywhere, 300.14 6" free lenght everywhere, 250.148 grd screws and splice all equip. grds together, 314.17 sheath shall extend 1/4" into box, 312.5 conn for GEC at p/s, 250.104 bond hot & cold water,110.3 install acorn grd clamp properly COW, told owner about creating more violations permit may be voided, if garage is not covered protect romex, install all boxes, complete all makeup, pull recepts and switches from boxes
|