Final | 1/12/2006 | 1/13/2006 | 1/13/2006 | A | PASS |
Pat Lass
|
|
|
lloyd; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa no card
|
Electrical Rough-In | 10/28/2005 | 10/31/2005 | 10/31/2005 | A | PASS |
William E Thomas
|
|
|
lloyd; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ri ok
|
Electrical Rough-In | 10/27/2005 | 10/28/2005 | 10/28/2005 | A | FAIL |
Mike Kinnear
|
|
|
lloyd; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa corrections not made 11/4 stapling,still missing outlet in hallway by kitchen, & missing outlet bathrm by back door next to garage. nec 210.53(D)
|
Electrical Rough-In | 10/26/2005 | 10/27/2005 | 10/27/2005 | A | FAIL |
Pat Lass
|
|
|
###-#### - lloyd nail plates and parallel protection of romex throughout especially outside walls. receps in upstairs bedrooms more than 6 ft from door and no recep on wall accross from kitchen island.
|
Permanent Service | 10/26/2005 | 10/27/2005 | 10/27/2005 | A | PASS |
Pat Lass
|
|
|
###-#### - lloyd P/S O/H N Ok
|