Final | 4/14/2006 | 4/14/2006 | 4/14/2006 | P | PASS |
Jack Frank
|
|
|
Garage code is 2468. please call paul@ ###-#### if any problems. Internet Inspection Request from: Paul Young ok corrections made
|
Final | 4/13/2006 | 4/13/2006 | 4/13/2006 | A | FAIL |
Jack Frank
|
|
|
Please call Brian Leavitt (builder) @###-#### before going over so access can be provided. thank you. Internet Inspection Request from: Paul Young corr. did not call, no number for electrical contractor 410.8 clearence closet under stairs, 314.16 box fill end of peninsular counter also protect romex, 210.52 needs outlet on kit circuit, fixed panel of slider over 6 ft
|
Electrical Rough-In | 11/28/2005 | 11/28/2005 | 11/28/2005 | P | PASS |
Mike Kinnear
|
|
|
Internet Inspection Request from: Paul Young ok cover ri
|
Electrical Rough-In | 11/27/2005 | 11/28/2005 | 11/28/2005 | A | FAIL |
Bob Reichert
|
|
|
give paul a call if any problems or questions. Internet Inspection Request from: Paul Young called contr, left corr notice,312.5 conductors shall have abrasion protection, 300.4(A) and (D) bored holes and nm cable shall be 1 1/4" from edge of framing member
|
Permanent Service | 11/28/2005 | 11/28/2005 | 11/28/2005 | P | PASS |
Mike Kinnear
|
|
|
Internet Inspection Request from: Paul Young p/s u/g n ok
|