Final | 8/15/2006 | 8/16/2006 | 8/16/2006 | A | PASS |
Pat Lass
|
|
|
###-#### please reinspect the c orrection list thank you steve; Phone #: ###-#### Internet Inspection Request from: steve creswell
|
Final | 8/13/2006 | 8/14/2006 | 8/14/2006 | P | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: steve creswell called, left message, left corr notice, nec 210.8(A)(C) island recpt shall be gfci protected,422.31(B) dishwasher shll have lockout, 410.6 luminaire shall be installed in dining room closet, 406.4(D) recpt face shall be flush with or project from faceplate, 406.5 recpt faceplates shall seat against finished surface, and be supplied at water softener and hw heater area, BCC dome over stairs shall be covered or finished, outside rear recpt shall operate correctly
|
Final | 7/23/2006 | 7/24/2006 | 7/24/2006 | P | NR |
Bob Reichert
|
|
|
the homeowner would like a temp c.o. I donot know if this is the right inspection. thanks; Phone #: ###-#### Internet Inspection Request from: steve creswell kitchen and baths not done, no disposals, ranges, ovens set, no sinks set, open boxes, can lites not done,main breakers not labelled, conduit riser not strapped, no fixture between garage and house,closet lamps upstairs over shelf spaces, no stair lighting, fixture in tub space not up, open boxes, called contr and went ver some of this, told contr and owner that if they move anything in, access shall be provided at least 3' around perimeter of room so inspection could be made
|
Final | 7/20/2006 | 7/21/2006 | 7/21/2006 | P | CANC |
Pat Lass
|
|
|
the homeowner wants to move in and would like a temperary c.o. the rest of the fixtures will be here then.; Phone #: ###-#### Internet Inspection Request from: steve creswell Inspection cancelled from web by: steve creswell
|
Rough-In Permanent Service | 3/25/2006 | 3/27/2006 | 3/27/2006 | A | PASS |
William E Thomas
|
|
|
please inspect the concrete for ufer ground and the service so we can swing power; Phone #: ###-#### Internet Inspection Request from: steve creswell p/s u/g n ok
|
Electrical Rough-In | 2/19/2006 | 2/21/2006 | 2/21/2006 | P | PASS |
Pat Lass
|
|
|
inspect bottom floor please; Phone #: ###-#### Internet Inspection Request from: steve creswell full R/I Ok
|
Rough-In Permanent Service | 2/8/2006 | 2/9/2006 | 2/9/2006 | P | PART |
Pat Lass
|
|
|
inspection for main floor,attatched garage and service. As late as possible please.; Phone #: ###-#### Internet Inspection Request from: steve creswell first floor ok
|
ELE-Request for Extension | 1/30/2006 | 1/31/2006 | 1/31/2006 | A | PASS |
Pat Lass
|
|
|
reinspection of upper floor,ufer ground; Phone #: ###-#### Internet Inspection Request from: steve creswell
|
Electrical Rough-In | 1/31/2006 | 1/31/2006 | 1/31/2006 | P | PART |
Pat Lass
|
|
|
reinspection of upper floor,ufer ground; Phone #: ###-#### Internet Inspection Request from: steve creswell 2nd floor ok Electrode ok for concrete
|
Electrical Rough-In | 1/28/2006 | 1/30/2006 | 1/30/2006 | A | FAIL |
Pat Lass
|
|
|
I need rough in on upper floor and service panels only.; Phone #: ###-#### Internet Inspection Request from: steve creswell
Concrete-Encased Electrode. 314.17 electrode entering the panel. 210.52 required recep in bedroom by door. 6 in free conductor
|