Permit Information
Permit NumberELE06-00091
StatusFinaled
Name ALWAYS WIRED
Site Address 4906 N QUAIL SUMMIT WAY
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - New: new wiring on 6366 sq. ft. home swimming pool done by others
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/15/20068/16/20068/16/2006APASS
DetailsPat Lass
###-#### please reinspect the c orrection list thank you steve; Phone #: ###-#### Internet Inspection Request from: steve creswell
Final8/13/20068/14/20068/14/2006PFAIL
DetailsBob Reichert
Phone #: ###-#### Internet Inspection Request from: steve creswell called, left message, left corr notice, nec 210.8(A)(C) island recpt shall be gfci protected,422.31(B) dishwasher shll have lockout, 410.6 luminaire shall be installed in dining room closet, 406.4(D) recpt face shall be flush with or project from faceplate, 406.5 recpt faceplates shall seat against finished surface, and be supplied at water softener and hw heater area, BCC dome over stairs shall be covered or finished, outside rear recpt shall operate correctly
Final7/23/20067/24/20067/24/2006PNR
DetailsBob Reichert
the homeowner would like a temp c.o. I donot know if this is the right inspection. thanks; Phone #: ###-#### Internet Inspection Request from: steve creswell kitchen and baths not done, no disposals, ranges, ovens set, no sinks set, open boxes, can lites not done,main breakers not labelled, conduit riser not strapped, no fixture between garage and house,closet lamps upstairs over shelf spaces, no stair lighting, fixture in tub space not up, open boxes, called contr and went ver some of this, told contr and owner that if they move anything in, access shall be provided at least 3' around perimeter of room so inspection could be made
Final7/20/20067/21/20067/21/2006PCANC
DetailsPat Lass
the homeowner wants to move in and would like a temperary c.o. the rest of the fixtures will be here then.; Phone #: ###-#### Internet Inspection Request from: steve creswell Inspection cancelled from web by: steve creswell
Rough-In Permanent Service3/25/20063/27/20063/27/2006APASS
DetailsWilliam E Thomas
please inspect the concrete for ufer ground and the service so we can swing power; Phone #: ###-#### Internet Inspection Request from: steve creswell
p/s u/g n ok
Electrical Rough-In2/19/20062/21/20062/21/2006PPASS
DetailsPat Lass
inspect bottom floor please; Phone #: ###-#### Internet Inspection Request from: steve creswell
full R/I Ok
Rough-In Permanent Service2/8/20062/9/20062/9/2006PPART
DetailsPat Lass
inspection for main floor,attatched garage and service. As late as possible please.; Phone #: ###-#### Internet Inspection Request from: steve creswell
first floor ok
ELE-Request for Extension1/30/20061/31/20061/31/2006APASS
DetailsPat Lass
reinspection of upper floor,ufer ground; Phone #: ###-#### Internet Inspection Request from: steve creswell
Electrical Rough-In1/31/20061/31/20061/31/2006PPART
DetailsPat Lass
reinspection of upper floor,ufer ground; Phone #: ###-#### Internet Inspection Request from: steve creswell
2nd floor ok
Electrode ok for concrete
Electrical Rough-In1/28/20061/30/20061/30/2006AFAIL
DetailsPat Lass
I need rough in on upper floor and service panels only.; Phone #: ###-#### Internet Inspection Request from: steve creswell

Concrete-Encased Electrode.
314.17 electrode entering the panel.
210.52 required recep in bedroom by door.
6 in free conductor